Use of conventional ECG electrodes for depth of anaesthesia monitoring using the cerebral state index: a clinical study in day surgery.

نویسندگان

  • R E Anderson
  • U Sartipy
  • J G Jakobsson
چکیده

BACKGROUND The cost-benefit relationship for depth of anaesthesia monitors is complicated by the high cost of specially designed EEG electrodes. The cerebral state index (CSI) monitor will accept regular ECG electrodes with snap connectors. The purpose of this study was to determine if generic ECG electrodes could replace the more expensive proprietary EEG electrodes for the CSI monitor. METHODS Two identical cerebral state monitors were used simultaneously during sevoflurane anaesthesia for knee arthroscopy in 14 ASA I-II patients. One monitor used proprietary (Danmeter) EEG electrodes and the other used ECG electrodes (3M Red Dot Diagnostic ECG Electrodes). Paired CSI values were recorded every other minute. Anaesthetic depth was titrated clinically. Sedation depth was scored according to the Observer's Assessment of Alertness/Sedation (OAAS) scale. RESULTS The agreement between the two measures was found to be high, mean difference--0.23, and the overall repeatability mean bias was 6.6 and 153/163 pairs (94%) were located within the 95% limits of agreement. No major difference was noted in impedance, noise, or artifacts. A large overlap in CSI was noted for each level of the OAAS scale; patients with CSI values as low as 40-50 responded whereas patients not responding to surgical stimulation had CSI values as high as 75. The direct cost of disposables decreased from 4euro to 0.50euro per patient by using ordinary ECG electrodes. CONCLUSIONS Switching from proprietary EEG electrodes to ordinary generic ECG electrodes maintains the same accuracy at about a 10th of the cost when measuring CSI during day surgery with sevoflurane anaesthesia.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Bispectral Index Monitoring Versus Clinical Judgment as a Guide for Conduction of Anesthesia on Serum Cortisol Level in Co-ronary Artery Bypass Graft Surgery

Background: Inadequate depth of anesthesia leads to release of stress hormones. Electroencephalographic monitoring by bispectral index is a guide to asses the depth of anesthesia. The aim of the present study was to measure the serum cortisol levels as an index of stress response in patients who are candidates for coronary artery bypass graft surgery in two groups of patients. Methods: Seventy-...

متن کامل

Periodic Indices of Serum Amyloid A Following Rumenotomy with Assorted Local Anaesthetics and Sutures in the Sahel Goat

Objective- This study aims at validating the use of serum amyloid A (SAA) as biomarkers of surgical stress using Quantitative ELISA in the Sahel goats. The experiment evaluated SAA profiles of Sahel goats post Diazepam-Lidocaine (DLC) and Diazepam-Bupivacaine (DBC) local anaesthesia. Expressions of SAA in the Sahel goat post rumen skin clamp fixation techniques of rumenotomy wi...

متن کامل

A comparison of bispectral index and entropy monitoring, in patients undergoing embolization of cerebral artery aneurysms after subarachnoid haemorrhage.

BACKGROUND Processed EEG monitoring of anaesthetic depth could be useful in patients receiving general anaesthesia following subarachnoid haemorrhage. We conducted an observational study comparing performance characteristics of bispectral index (BIS) and entropy monitoring systems in these patients. METHODS Thirty-one patients of the World Federation of Neurosurgeons grades 1 and 2, undergoin...

متن کامل

Can electrocardiogram electrodes replace bispectral index electrodes for monitoring depth of anesthesia?

BACKGROUND Bispectral index has been introduced to provide optimal level of anesthesia. However, Bispectral index monitoring may not be cost effective in a relatively short procedures due to the high costs of the electrode. The authors conducted the present study to compare the feasibility of commercially available electrocardiogram (ECG) electrodes instead of the Bispectral index (BIS) monitor...

متن کامل

Clinical and Cost-Effectiveness and Budget Impact of Routine Use of Bispectral Index Monitors In Theatres.

A cost utility analysis and budget impact (BI) were developed using a decision model to compare the incremental outcomes and costs of monitoring the depth of anaesthesia with BIS monitors compared with using clinical signs, electrocardiography (ECG) and other devices (standard clinical monitoring) over a five-year period. The health outcomes included are utility values associated with adverse e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 98 5  شماره 

صفحات  -

تاریخ انتشار 2007