A restrictive inflow pattern does not predict implantable cardioverter-defibrillator therapy in primary prevention.
نویسندگان
چکیده
BACKGROUND Current guidelines for the use of implantable cardioverter-defibrillators (ICDs) are broad and significantly increase the cost of caring for patients with heart failure. In an effort to identify the specific subset of patients who benefit from this therapy, the predictive value of numerous echocardiographic parameters have been studied. Severe diastolic dysfunction has been shown to predict adverse events in a group of patients who received an ICD for secondary prevention, but has not been tested in those who receive ICDs for primary prevention. HYPOTHESIS We tested the hypothesis that a restrictive mitral inflow pattern on echocardiography will predict the risk of appropriate therapy in this patient population. METHODS This retrospective study identified 145 consecutive patients who met primary prevention criteria for ICD implantation and had an echo performed no more than 1 year prior to receiving the ICD. A restrictive pattern was defined as a mitral inflow E/A > 2 or a deceleration time < 150 ms. RESULTS A restrictive pattern was present in 69 patients (40.7% of the group). Appropriate ICD therapy occurred in 8 (11.5%) subjects with a restrictive pattern and 14 (18.4%) with a nonrestrictive pattern over 680 days of average follow-up (P = not significant). Cox regression analysis showed the presence of a restrictive pattern was not helpful in predicting time to first ICD therapy. CONCLUSIONS In a population of patients who received ICDs for primary prevention, echocardiographic findings of severe diastolic dysfunction were not helpful in targeting the use of ICDs to those at highest risk.
منابع مشابه
Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملDefibrillator implantation for the primary prevention of sudden death in patients awaiting cardiac transplantation: one center's experience.
Patients who are on a waiting list for cardiac transplantation often have a clinical profile that satisfies current recommendations for the implantation of an implantable cardioverter-defibrillator for the primary prevention of sudden death. The prospect that transplantation may take place within the short-to-medium term puts the effectiveness of this therapy in doubt. We investigated the incid...
متن کاملImprovements in 25 Years of Implantable Cardioverter Defibrillator Therapy
In 1980, Dr. Michel Mirowski and his team inserted the first implantable cardioverter defibrillator (ICD) in a patient. Initially, ICD therapy was not widely accepted, and many physicians actually considered this therapy unethical. Large secondary and primary prevention trials, demonstrating a beneficial effect of ICD therapy in selected patients not only on arrhythmic death but also on all-cau...
متن کاملEffectiveness of Implantation of Cardioverter-Defibrillators Therapy in Patients with Non-Ischemic Heart Failure: an Updated Systematic Review and Meta-Analysis
OBJECTIVE Implantable cardioverter-defibrillator has become the first-line therapy for prevention of sudden cardiac death. Controversial results still exist regarding the effectiveness of implantable cardioverter-defibrillator (ICD) in non-ischemic heart failure. METHODS The PubMed, Embase, and Cochrane Central databases were searched for randomized trials comparing implantable cardioverter-d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical cardiology
دوره 32 12 شماره
صفحات -
تاریخ انتشار 2009