SEISMIC ANALYSIS MODELING TO SATISFY BUILDING CODES The Current Building Codes Use the Terminology: Principal Direction without a Unique Definition

ثبت نشده
چکیده

{ XE "Building Codes" }Currently a three-dimensional dynamic analysis is required for a large number of different types of structural systems that are constructed in Seismic Zones 2, 3 and 4 [1]. The lateral force requirements suggest several methods that can be used to determine the distribution of seismic forces within a structure. However, these guidelines are not unique and need further interpretations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating The Seismic Response of Structural Walls Using Nonlinear Static and Incremental Dynamic Analyses

Structural walls commonly used as efficient structural elements to resist lateral and vertical loads. Diverse performance of bearing wall system in past earthquakes, motivates investigation on the adequacy of current seismic design provision for these walls. This study considers seismic performance of model walls of bearing wall and building frame systems designed as ordinary and special struct...

متن کامل

Application of Near Surface Mounted (NSM) technique for Seismic Retrofitting of Heritage Buildings

The high vulnerability of the cultural buildings due to seismic actions urged researchers to retrofit them using reversible and compatible techniques. The application of fiber reinforced polymer (FRP) for enhancing the structural behavior of masonry buildings, under seismic actions, has been studied by many researchers. The near-surface mounting (NSM) technique is a relatively new retrofitting ...

متن کامل

Evaluating Response Modification Factors of Concentrically Braced and Special Moment Steel Frames in Duplex Buildings

Response modification factor (R-factor) is one of the seismic design parameters to consider nonlinear performance of building structures during strong earthquake. Relying on this, many seismic design codes led to reduce earthquake loads imposed to the structure. The present paper tries to evaluate the R-factors of conventional concentric braced frames (CBFs) and special moment frames (MRFs) in ...

متن کامل

بررسی و ارزیابی عملکرد مقررات ملی ساختمان با رویکرد ایمنی حریق در بخش‌های بستری یک بیمارستان

Background and aimsAIDS as a re-emergent disease and Viral hepatitis (B and C) as one of thBackground and objective: Fire safety is an important problem in hospitals. Movement less, lack of awareness and special situation of residents are the reasons of this subject. In more countries such as Iran, fire protection regulations have compiled within the framework of national building codes. Curren...

متن کامل

Seismic Evaluation and Retrofit of Gas Stations: Case Study

Iran is a country with high seismicity while Tehran, the capital city is home to more than 10 million people which are located on the highest seismic zone of the country. There exist 153 gas stations throughout the metropolitan which are constructed to old building codes with little or no attention to the seismic considerations. In this study which was supported by the National Oil Company, fir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011