Analytical Investigations in Magnetic Recording by Stephen

نویسندگان

  • J. C. BROWN
  • STEPHEN JAMES CHARLES BROWN
چکیده

The Fourier method is used to provide new analytic solutions for idealized mathematical models of double-element shielded magnetoresistive (MR) recording heads. The general two-dimensional model allows analysis of various recording head configurations; a single pole head, a ring head, a dual stripe head and a differential head. The analysis accommodates both longitudinal recording (with no soft magnetic underlayer present) and perpendicular recording (in the presence of a soft underlayer). Typical field, spectral response function and output voltage pulse plots for doubleelement MR heads are given and compared to published, approximate solutions. The integrals arising in the determination of the Fourier series coefficients, magnetic potential and magnetic field components are expressed either as rapidly convergent infinite series or in terms of special functions to provide a more efficient means of evaluation than numerical integration. It is shown that, in many situations, it is only necessary to take the first Fourier coefficient in the calculation of output voltage pulse shapes in order to achieve sufficiently accurate results. Bi-variate regression techniques are used to provide a convenient method to approximate the first Fourier series coefficient for a broad range of typical head dimensions. The thesis goes on to examine high speed switching behaviour in two classes of recording media by considering two different particle orientation distributions; 2D random media intended to simulate a modern thin film rigid disk, and 3D oriented mediasimulating a single domain particulate tape media. The gyromagnetic switching constant of a medium is calculated directly from the Landau Lifshitz Gilbert (L-L-G) equation of motion, which is solved numerically. The switching constants produced are discussed and compared with published experimental values for different media.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The investigation of nanostructures of magnetic recording media by TEM

Diverse applications of transmission electron microscopy techniques used in investigating the nanostructures of magnetic recording materials are presented. Specimen preparation methods are discussed for the specific case of magnetic thin film recording media. Investigations of the crystallographic orientation, grain size and distribution, and interfacial nanostructures are presented. 2003 Acta ...

متن کامل

Analytical read back signal modeling in magnetic recording

An analytical model for the read back signal is derived for perpendicular and longitudinal magnetic recording. The model captures the contribution of a single bit rather than the contribution of a bit transition which makes it applicable to patterned media as well as continuous media. It is based on the law of Biot–Savart and separates the contribution of the magnetic media from the head sensit...

متن کامل

Investigations of Microstructures and Magnetic Properties through Off-time between Pulses and Controlled Cu Content in Pulse Electrodeposited NiCu Nanowires

NiCu alloy nanowires arrays were embedded into the anodic aluminum oxide (AAO) template by ac-pulse electrodeposition. Different off-time were used in electrolyte with constant concentration of Ni and Cu and acidity of 3. The effect of deposition parameters on alloy contents was investigated by studying the microstructure and magnetic properties of as-deposited NiCu alloy nanowires. Atomic forc...

متن کامل

Recent analytical applications of magnetic nanoparticles

Analytical chemistry has experienced, as well as other areas of science, a big change due to the needs and opportunities provided by analytical nanoscience and nanotechnology. Now, nanotechnology is increasingly proving to be a powerful ally of analytical chemistry to achieve its objectives, and to simplify analytical processes. Moreover, the information needs arising from the growing nanotechn...

متن کامل

Investigations of Magnetic Properties Through Electrodeposition Current and Controlled Cu Content in Pulse Electrodeposited CoFeCu Nanowires

CoFeCu nanowires were deposited by pulsed electrodeposition technique into the porous alumina templates by a two-step mild anodization technique, using the single-bath method. The electrodeposition was performed in a constant electrolyte while Cu constant was controlled by electrodeposition current. The electrodeposition current was 3.5, 4.25, 5 and 6 mA. The effect of electrodeposition current...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013