A critical evaluation of the Mefar dosimeter.

نویسندگان

  • R J Ward
  • P Liakakos
  • R F Leonard
  • D W Reid
  • D P Johns
  • E H Walters
چکیده

Multicentre studies of airway responsiveness (AR) are increasingly important tools in asthma epidemiology. Because comparisons of AR are made between centres it is essential that measurement techniques are accurate and standard. This study investigated the Mefar dosimeter which is currently used in the 35 centre European Community Respiratory Health Survey (ECRHS) with the next phase currently being planned. Significant differences were found in driving pressures and aerosol outputs between the three Mefar dosimeters in the laboratory. A linear relationship was also found between driving pressure and aerosol output (R2=0.96). These differences are important as they may lead to variations between centres of < or =35% in the drug dose delivered in AR measurement, which could potentially diminish the power of individual study centres to accurately detect national differences in AR. Dosimeter driving pressure and nebulizer output should be standardized in future studies of airway responsiveness. With relatively simple quality control measures in place it is believed that the Mefar dosimeter can produce reliable between-centre longitudinal data with an increase in the accuracy of these important studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of two standardized methods of methacholine inhalation challenge in young adults.

In the European Community Respiratory Health Study (ECRHS), airway responsiveness to methacholine was determined using the Mefar dosimeter protocol. Elsewhere, the 2-min tidal breathing method has become the preferred standardized method. The relationship between measurements of responsiveness by these two methods is not well established. This study measured airway responsiveness to methacholin...

متن کامل

European Community Respiratory Health Survey calibration project of dosimeter driving pressures.

Two potential sources of systematic variation in output from Mefar dosimeters, the system used in the European Community Respiratory Health Survey (ECRHS) study have been evaluated: individual nebulizer characteristics and dosimeter driving pressure. Output variation from 366 new nebulizers produced in two batches for the second ECRHS were evaluated, using a solute tracer method, at a fixed dri...

متن کامل

Calibration of aerosol output from the Mefar dosimeter: implications for epidemiological studies.

Standardized methods for the measurement of airway responsiveness may use the Mefar MB3 inhalation dosimeter to generate standard doses of methacholine aerosol. The manufacturer provides calibrated output data for every nebulizer, so that a standard output may be achieved by varying nebulization time. This output is, however, measured by weight loss (WL), which may over-estimate true aerosol ou...

متن کامل

A comparison of the Yan and a dosimeter method for methacholine challenge in experienced and inexperienced subjects.

Bronchial reactivity is being measured with increasing frequency in epidemiological studies, but there debate continues about the relative merits of the different methods used to measure reactivity, particularly for subjects with no previous experience of reactivity testing as is the case in epidemiological studies. Repeatability is likely to improve with practice, and laboratory based studies ...

متن کامل

Evaluation of Breast Cancer Radiation Therapy Techniques in Outfield Organs of Rando Phantom with Thermoluminescence Dosimeter

Background: Given the importance of scattered and low doses in secondary cancer caused by radiation treatment, the point dose of critical organs, which were not subjected to radiation treatment in breast cancer radiotherapy, was measured.Objective: The purpose of this study is to evaluate the peripheral dose in two techniques of breast cancer radiotherapy with two energies. Methods: Eight diff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 14 2  شماره 

صفحات  -

تاریخ انتشار 1999