Field calibrations of a long-term UV dosimeter for aquatic UVB exposures.

نویسندگان

  • P W Schouten
  • A V Parisi
  • D J Turnbull
چکیده

Various methodologies using a wide range of measurement systems have been employed previously in order to determine the amount of UV that could be incident upon various aquatic organisms in a number of different aquatic locales. Broadband meters and spectroradiometers have been employed extensively to take underwater measurements. However, these measurement campaigns are limited by the fact that radiometric equipment requires a human controller, constant power supply and regular calibrations and corrections in order to function properly. Dosimetric measurements have also been made underwater using two distinct types of dosimeter. The first type based on a synthetic chemical, like polysulphone, and the second type based on a biological matter, such as a DNA sample. The studies made using biological dosimeters have displayed very good results, however the time and skill necessary to make these types of dosimeters can outweigh their usefulness. The chemical dosimeters are easier to make and have also provided useable data, but only for short periods of exposure, usually no more than a day. Previous research has shown that Poly (2,6-dimethyl-1,4-phenylene oxide) (PPO) has excellent potential for use as a long-term underwater solar UVB dosimeter. However, there is no documented methodology on how to properly calibrate the PPO dosimeter for water-based measurements and it has yet to be trialled in an outdoors marine environment, either real or simulated. This manuscript shows that calibrations obtained in air can not be transferred to calibrations made in water, calibrations made in one type of water can be employed for another type of water, but only within a certain range of spectral transmission and calibrations made at different depths in the same water type are interchangeable. It was also discovered that changing solar zenith angle had an effect upon calibration data. This research addressed these issues by formulating and developing a calibration methodology required for accurate underwater long-term UVB measurements in the field using the PPO film dosimeter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a Long Term Solar UVA Dosimeter

Exposure to UV radiation is known to be a causative factor in the induction of skin cancers and other sun-related disorders. Most acute responses of humans to UV exposure occur as a result of UVB (280 to 315 nm) exposures, as these wavelengths are highly sensitive in creating a human biological response. However, this does not mean that UVA radiation has no impact on human UV exposures and heal...

متن کامل

Applicability of the polyphenylene oxide film dosimeter to high UV exposures in aquatic environments.

Previous research has proven that the Poly (2,6-dimethyl-1, 4-phenylene oxide) (PPO) dosimeter is capable of receiving both in-air and underwater UV exposures that are significantly greater than those of the more commonly used polysulphone dosimeter, within a range of accuracy close to what would be expected of dosimetric measurements made in-air provided that the necessary calibrations are com...

متن کامل

Utilising polyphenylene oxide for high exposure solar UVA dosimetry

A personal UV dosimeter that can quantitatively assess high exposure solar UVA exposures has been developed. The chemical polyphenylene oxide has been previously reported on its ability to measure high UVB exposures. This current research has found that polyphenylene oxide, cast in thin film form, is responsive to both the UVA and UVB parts of the solar spectrum. Further to this, the UVB wavele...

متن کامل

Ultraviolet B Radiation Induced Alterations in Immune Function of Fish In Relation to Habitat Preference and Disease Resistance

Markkula, Eveliina Ultraviolet B radiation induced alterations in immune function of fish, in relation to habitat preference and disease resistance Jyväskylä: University of Jyväskylä, 2009, 50 p. (Jyväskylä Studies in Biological and Environmental Science ISSN 1456-9701; 204) ISBN 978-951-39-3677-8 (PDF), 978-951-39-3651-8 (nid.) Yhteenveto: Ultravioletti B -säteilyn vaikutus kalan taudinvastust...

متن کامل

Dosimeter for measurement of UVA exposures

A prototype UVA dosimeter that is responsive to the UVA wavelengths only has been developed for measurement of personal exposures. The chemical phenothiazine, cast in thin film form and which is responsive to both the UVA (320400 nm) and UVB (280-320 nm) part of the spectrum was used and filtered with mylar. This combined system responded to the UVA wavelengths only and underwent a change in op...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of photochemistry and photobiology. B, Biology

دوره 91 2-3  شماره 

صفحات  -

تاریخ انتشار 2008