Particle Size-Selective Assessment of Protection of European Standard FFP Respirators and Surgical Masks against Particles-Tested with Human Subjects
نویسندگان
چکیده
This study was conducted to investigate the protection of disposable filtering half-facepiece respirators of different grades against particles between 0.093 and 1.61 μm. A personal sampling system was used to particle size-selectively assess the protection of respirators. The results show that about 10.9% of FFP2 respirators and 28.2% of FFP3 respirators demonstrate assigned protection factors (APFs) below 10 and 20, which are the levels assigned for these respirators by the British Standard. On average, the protection factors of FFP respirators were 11.5 to 15.9 times greater than those of surgical masks. The minimum protection factors (PFs) were observed for particles between 0.263 and 0.384 μm. No significant difference in PF results was found among FFP respirator categories and particle size. A strong association between fit factors and protection factors was found. The study indicates that FFP respirators may not achieve the expected protection level and the APFs may need to be revised for these classes of respirators.
منابع مشابه
Performance of Facepiece Respirators and Masks against Surgical Smoke: SWPF Study
Healthcare workers in operating rooms are often exposed to surgical smoke when surgical and invasive procedures are performed by using laser or other devices that interact with tissue. Potentially infectious viruses, bacteria, and hazardous chemicals are found in surgical smoke, which are associated with several respiratory diseases including chronic cough, throat irritation, and asthma. Additi...
متن کاملIssues Affecting Respirator Selection for Workers Exposed to Infectious Aerosols: Emphasis on Healthcare Settings
The goal of occupational health practice is to protect the health of workers by preventing diseases and injuries from occurring. When work activities are anticipated, recognized, or found during an investigation to involve risks to workers’ health, preventive measures should be taken to control hazardous exposures in the workplace. Respirators are often used to control inhalational exposures to...
متن کاملSmall-particle aerosolization of live attenuated influenza vaccine virus.
To the Editor—In their recent study, Bischoff et al [1] exposed subjects to a small-particle aerosol of commercially available live attenuated influenza vaccine (LAIV; MedImmune LLC, Gai-thersburg, MD). LAIV was used as a proxy for wild-type influenza to evaluate the protection provided by N95 respirators, surgical masks, and eye protection. Although the study addresses the important question o...
متن کاملRespirator fit-testing - will we pass the test?
The UK Health Protection Agency advises health care workers caring for patients with probable or confirmed flu-like illnesses, with serious respiratory illnesses or where aerosol generating procedures are being undertaken to use a filtering face piece-3 (FFP3) respirator [1]. Whereas masks protect the environment from wearers, respirators by design protect wearers from the environment. Some sur...
متن کاملComparison of Simulated Workplace Protection Factors Offered by N 95 and P 100 Filtering Facepiece and Elastomeric Half - Mask Respirators
This study compared the simulated workplace protection factors (SWPFs) between NIOSH-approved N95 respirators and P100 respirators, including two models of filtering facepiece respirator (FFR) and two models of elastomeric halfmask respirator (EHR),against sodium chloride particles (NaCl) in a range of 10 to 400 nm. Twenty-five human test subjects performed modified OSHA fit test exercises in a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016