Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density?

نویسندگان

  • Y. P. Acklin
  • I. Zderic
  • S. Grechenig
  • R. G. Richards
  • P. Schmitz
  • B. Gueorguiev
چکیده

OBJECTIVES Osteosynthesis of anterior pubic ramus fractures using one large-diameter screw can be challenging in terms of both surgical procedure and fixation stability. Small-fragment screws have the advantage of following the pelvic cortex and being more flexible.The aim of the present study was to biomechanically compare retrograde intramedullary fixation of the superior pubic ramus using either one large- or two small-diameter screws. MATERIALS AND METHODS A total of 12 human cadaveric hemipelvises were analysed in a matched pair study design. Bone mineral density of the specimens was 68 mgHA/cm3 (standard deviation (sd) 52). The anterior pelvic ring fracture was fixed with either one 7.3 mm cannulated screw (Group 1) or two 3.5 mm pelvic cortex screws (Group 2). Progressively increasing cyclic axial loading was applied through the acetabulum. Relative movements in terms of interfragmentary displacement and gap angle at the fracture site were evaluated by means of optical movement tracking. The Wilcoxon signed-rank test was applied to identify significant differences between the groups RESULTS: Initial axial construct stiffness was not significantly different between the groups (p = 0.463). Interfragmentary displacement and gap angle at the fracture site were also not statistically significantly different between the groups throughout the evaluated cycles (p ⩾ 0.249). Similarly, cycles to failure were not statistically different between Group 1 (8438, sd 6968) and Group 2 (10 213, sd 10 334), p = 0.379. Failure mode in both groups was characterised by screw cutting through the cancellous bone. CONCLUSION From a biomechanical point of view, pubic ramus stabilisation with either one large or two small fragment screw osteosynthesis is comparable in osteoporotic bone. However, the two-screw fixation technique is less demanding as the smaller screws deflect at the cortical margins.Cite this article: Y. P. Acklin, I. Zderic, S. Grechenig, R. G. Richards, P. Schmitz, B. Gueorguiev. Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density? Bone Joint Res 2017;6:8-13. DOI: 10.1302/2046-3758.61.BJR-2016-0261.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk of Spermatic Cord Injury During Anterior Pelvic Ring and Acetabular Surgery: An Anatomical Study

  Background: Anterior pelvic ring surgery includes a variety of plating techniques and insertion of retrograde superior pubic ramus screws. Anterior acetabular surgery also includes fixation through an ilioinguinal or Stoppa approach. These exposures risk injury to the spermatic cord and accompanying genital branch of the genitofemoral nerve. The primary aim of this study was to identify the d...

متن کامل

Biomechanical comparison of headless antegrade screw versus retrograde cortical screw for coronoid fracture fixation.

OBJECTIVE Posterior-to-anterior directed screws are stronger than anterior-to-posterior directed screws for coronoid fracture fixation. Anterior approaches that facilitate direct reduction and fixation of coronoid fractures have been described. The present study was based on the hypothesis that anterior-to-posterior headless screw (Acutrak Mini® 3.5 mm × 26 mm, Acumed, Hillsboro, Oregon, USA) f...

متن کامل

Biomechanical Comparison of Four Different Fixation Techniques in Sacrum Denis Type Ii Fractures

1. AO Research Institute Davos, Davos, Switzerland; 2. University Hospital Regensburg, Regensburg, Germany Introduction Unstable pelvic ring injuries treated conservatively are associated with long hospitalization, inappropriate fragment reduction and a high mortality rate [1]. Surgical intervention with percutaneous sacroiliac (SI) screws combined with anterior pelvic plating has shown a high ...

متن کامل

Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference

BACKGROUND Due to complex pelvic geometry, percutaneous screw placement in the posterior acetabular column can pose a major challenge even for experienced surgeons. METHODS The present study examined the preformed bone stock of the posterior acetabular column in 260 hemipelvises. Retrograde posterior column screws were virtually implanted using iPlan CMF (BrainLAB AG, Feldkirchen, Germany); m...

متن کامل

Biomechanical study of 4-hole pubic symphyseal plating: locked versus unlocked constructs.

To the authors' knowledge, no published studies have examined the use of locking plates on injuries of the anterior pelvic ring. The purpose of this study was to determine whether locked plates provide enhanced stability in the treatment of pubic symphyseal disruptions. Completely unstable pelvic injuries were simulated in pelvic Sawbones (model 1301; Pacific Research Laboratories, Vashon, Wash...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017