Comparison of approaches to correct intake–health associations for FFQ measurement error using a duplicate recovery biomarker and a duplicate 24 h dietary recall as reference method.

نویسندگان

  • Anouk Geelen
  • Olga W Souverein
  • Maria C Busstra
  • Jeanne H M de Vries
  • Pieter van't Veer
چکیده

OBJECTIVE To illustrate the impact of intake-related bias in FFQ and 24 h recall (24hR), and correlated errors between these methods, on intake-health associations. DESIGN Dietary intake was assessed by a 180-item semi-quantitative FFQ and two 24hR. Urinary N and urinary K were estimated from two 24 h urine samples. We compared four scenarios to correct associations for errors in an FFQ estimating protein and K intakes. SETTING Wageningen, The Netherlands. SUBJECTS Fifty-nine men and fifty-eight women aged 45–65 years. RESULTS For this FFQ, measurement error weakened a true relative risk of 2·0 to 1·4 for protein and 1·5 for K. As compared with calibration to duplicate recovery biomarkers (i.e. the preferred scenario 1), estimating a validity coefficient using this duplicate biomarker resulted in overcorrected associations, caused by intake-related bias in the FFQ (scenario 2). The correction factor based on a triad using biomarkers and 24hR was hampered by this intake-related bias and by correlated errors between FFQ and 24hR, and in this population resulted in a nearly perfect correction for protein but an overcorrection for K (scenario 3). When the 24hR was used for calibration, only a small correction was done, due to correlated errors between the methods and intake-related bias in the 24hR (scenario 4). CONCLUSIONS Calibration to a gold standard reference method is the preferred approach to correct intake-health associations for FFQ measurement error. If it is not possible to do so, using the 24hR as reference method only partly removes the errors, but may result in improved intake-health associations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reducing Measurement Error in Nutrition Assessment: Potential Research Implications for Iran

Self-reported measures of dietary intake are prone to measurement error that may obscure the relationship of diet and disease. This review addresses strategies to decrease errors during collection of dietary data and statistical approaches to deal with measurement issues once the data are collected.  Examples from two US studies-- the Women’s Health Initiative (WHI) Dietary Modificat...

متن کامل

Empirical evidence of correlated biases in dietary assessment instruments and its implications.

Multiple-day food records or 24-hour recalls are currently used as "reference" instruments to calibrate food frequency questionnaires (FFQs) and to adjust findings from nutritional epidemiologic studies for measurement error. The common adjustment is based on the critical requirements that errors in the reference instrument be independent of those in the FFQ and of true intake. When data on uri...

متن کامل

Bias in dietary-report instruments and its implications for nutritional epidemiology.

OBJECTIVE To evaluate measurement error structure in dietary assessment instruments and to investigate its implications for nutritional studies, using urinary nitrogen excretion as a reference biomarker for protein intake. DESIGN The dietary assessment methods included different food-frequency questionnaires (FFQs) and such conventional dietary-report reference instruments as a series of 24-h...

متن کامل

Structure of dietary measurement error: results of the OPEN biomarker study.

Multiple-day food records or 24-hour dietary recalls (24HRs) are commonly used as "reference" instruments to calibrate food frequency questionnaires (FFQs) and to adjust findings from nutritional epidemiologic studies for measurement error. Correct adjustment requires that the errors in the adopted reference instrument be independent of those in the FFQ and of true intake. The authors report da...

متن کامل

A New Method for Duplicate Detection Using Hierarchical Clustering of Records

Accuracy and validity of data are prerequisites of appropriate operations of any software system. Always there is possibility of occurring errors in data due to human and system faults. One of these errors is existence of duplicate records in data sources. Duplicate records refer to the same real world entity. There must be one of them in a data source, but for some reasons like aggregation of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Public health nutrition

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 2015