Generally, codes and standards require that distributed generators detect when they have been separated from the main grid, and cease to energize any part of the local electric power system in that case. Industry has responded by developing a variety of means for preventing unintentional islands, which are generally highly effective in cases with small numbers of inverters from a single manufacturer. However, as deployment levels of distributed generators increase, utilities are becoming concerned that islanding detection schemes may lose effectiveness on feeders on which there are inverters from multiple manufacturers, or if there is a mixture of inverters and rotating machines. This paper reviews the latest in islanding detection schemes, presents a number of study results in which these two problem cases are examined, and briefly discuss the future of islanding detection and how this problem will ultimately be solved. The two key conclusions of the paper are: a) that the two cases mentioned above sometimes do lead to elevated run-on times and concerns about these cases are legitimate; and b) the ultimate solution to the islanding detection problem is likely to be a communications-based method, backed up by advanced passive methods used in combination.
منابع مشابه
Islanding Detection for Photovoltaic Inverters Using the Sandia Frequency Shift Method
The connection of inverters for distributed generation photovoltaic systems to the distribution network creates situations of risk to the loads that are connected to the point of common coupling (PCC) and personals who maintain the power grid. A risk that should be avoided is the supply of electricity, by one or more inverters, to the distribution network after disconnecting the main power grid...
متن کاملروشی جدید در تحلیل عملکرد حفاظت های ضدجزیره ای فرکانسی در حالت جزیرهای چند اینورتری
Because of high penetration of distributed resources in the distribution networks, the analysis of islanding protection in the multiple inverters situation has become of a great importance. In this paper a new method which analyzes the frequency based anti-islanding protection in the multiple inverters situation, is presented. The method has wide domain of applicability and analyzes the operati...
متن کاملLoad Sharing Control of Parallel Inverters with Uncertainty in the Output Filter Impedances for Islanding Operation of AC Micro-Grid
Parallel connection of inverter modules is a solution to increase reliability, efficiency and redundancy of inverters in Micro-Grid system. Proper load sharing among parallel inverters is a key point. The circulating current among the inverters can greatly reduce the efficiency or even cause instability of the system. In this paper, a control strategy for improving the load sharing performance ...
متن کاملالگوریتمی جدید برای جزیره بندی کنترل شده سیستم های قدرت مبتنی بر خوشه بندی طیفی مقید
In this paper a new algorithm is presented for power systems controlled islanding based on constrained spectral clustering. The proposed algorithm minimizes two objective functions of power flow disruption in transmission lines and generation - demand imbalance in islands to ensure transient stability within islands and to minimize necessary actions in reconfiguration of transmission system, ge...
متن کاملSuggested Guidelines for Assessment of DG Unintentional Islanding Risk
As increasing numbers of Distributed Generation (DG) systems are connected to utility systems, distribution engineers are becoming increasingly interested in evaluating the risk of unintentional islanding. Utilities desire to keep their systems secure, while not imposing unreasonable burdens on customers wishing to connect DG. However, utility experience with these systems is still relatively s...
متن کامل