The effect of body mass and sex on the accuracy of respiratory magnetometers for measurement of end-expiratory lung volumes.

نویسندگان

  • Joanne Avraam
  • Rosie Bourke
  • John Trinder
  • Christian L Nicholas
  • Danny Brazzale
  • Fergal J O'Donoghue
  • Peter D Rochford
  • Amy S Jordan
چکیده

Respiratory magnetometers are increasingly being used in sleep studies to measure changes in end-expiratory lung volume (EELV), including in obese obstructive sleep apnea patients. Despite this, the accuracy of magnetometers has not been confirmed in obese patients nor compared between sexes. Thus we compared spirometer-measured and magnetometer-estimated lung volume and tidal volume changes during voluntary end-expiratory lung volume changes of 1.5, 1, and 0.5 l above and 0.5 l below functional respiratory capacity in supine normal-weight [body mass index (BMI) < 25 kg/m] and healthy obese (BMI > 30 kg/m) men and women. Two different magnetometer calibration techniques proposed by Banzett et al. [Banzett RB, Mahan ST, Garner DM, Brughera A, Loring SH. J Appl Physiol (1985) 79: 2169-2176, 1995] and Sackner et al. [Sackner MA, Watson H, Belsito AS, Feinerman D, Suarez M, Gonzalez G, Bizousky F, Krieger B. J Appl Physiol (1985) 66: 410-420, 1989] were assessed. Across all groups and target volumes, magnetometers overestimated spirometer-measured EELV by ~65 ml (<0.001) with no difference between techniques (0.07). The Banzett method overestimated the spirometer EELV change in normal-weight women for all target volumes except +0.5 l, whereas no differences between mass or sex groups were observed for the Sackner technique. The variability of breath-to-breath measures of EELV was significantly higher for obese compared with nonobese subjects and was higher for the Sackner than Banzett technique. On the other hand, for tidal volume, both calibration techniques underestimated spirometer measurements (<0.001), with the underestimation being more marked for the Banzett than Sackner technique (0.03), in obese than normal weight (<0.001) and in men than in women (0.003). These results indicate that both body mass and sex affect the accuracy of respiratory magnetometers in measuring EELV and tidal volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The accuracy of FEF25-75/ FVC for primary classification of the pulmonary function test

Introduction: The forced expiratory flow at 25 and 75% of the pulmonary volume/forced vital capacity ratio (FEF25-75/FVC) as a spirometry parameter has been successful in the early diagnosis of chronic obstructive pulmonary disease (COPD) and the methacholine challenge test for assessing airway responsiveness.To determine the accuracy of FEF25-7...

متن کامل

Evaluation of Superiority of FEV1/VC Over FEV1/FVC for Classification of Pulmonary Disorders

Introduction: Forced expiratory value in one score  (FEV1)/ Forced vital capacity (FVC) was used in classical literature for primary classifications of pulmonary disorders. American Thoracic Society/ European Respiratory Society guidelines recommended using FEV1/VC instead of FEV1/FVC.The aim of study was determination of the extent of superiority of FEV1/VC over the FEV1/FVC. Materials and Met...

متن کامل

تأثیر تهویه با حجم‌های جاری متفاوت و تهویه دقیقه‌ای ثابت بر روی دی‌اکسید کربن انتهای بازدمی

Background & Aims: Elimination of carbon dioxide is related to the alveolar ventilation, respiratory rate and tidal volume. The aim of this study  to determine the effect of mechanical ventilation with different tidal volumes and constant minute ventilation on the end tidal Co2  and oxygen saturation during general anesthesia and to seek optimum parameters of mechanical ventilation during gener...

متن کامل

Population values of lung volumes and flows in children: effect of sex, body mass and respiratory conditions.

The functional relationship of gender, anthropometric measures and respiratory condition in predicting respiratory function in children was explored, using data collected in a random sample survey in Central Italy (2,176 subjects). Regression equations for the logarithmic transformation of the functional data were obtained, using sex, ln(height), ln(body mass index) (BMI) and ln(age) as predict...

متن کامل

بررسی همبستگی بین کیفیت خواب با شاخص‌های تنفسی و شاخص توده بدنی در دانشجویان پسر فعال و غیر فعال دانشگاه محقق اردبیلی در سال 1396

Background and Objectives: Poor sleep quality can cause a variety of problems, including reduced lung function and increased obesity. Therefore, the aim of this study was to investigate the relationship between sleep quality and respiratory index and BMI (Body Math Index) in active and inactive male students of Mohaghegh Ardabili University in 2017. Materials and Methods: In this descriptive s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 121 5  شماره 

صفحات  -

تاریخ انتشار 2016