Efficacy and safety of the pars plana clip in the Ahmed valve device inserted via the pars plana in patients with refractory glaucoma

نویسندگان

  • Manuel Diaz-Llopis
  • David Salom
  • Salvador García-Delpech
  • Patricia Udaondo
  • Jose Maria Millan
  • J Fernando Arevalo
چکیده

PURPOSE To evaluate the efficacy and safety of the pars plana clip (PPC) in the Ahmed valve tube inserted via the pars plana in patients with secondary refractory glaucomas. METHODS Prospective and interventional case series that included 10 patients with secondary refractory glaucoma. The pars plana vitrectomy and the implant of the modified tube were performed during the same surgery. Control of intraocular pressure (IOP) and the development of intra- and postoperative complications were evaluated during the follow-up. RESULTS Follow-up time was twelve months in all the patients. Control of IOP was achieved in 90% of patients, and 70% needed no antiglaucoma treatment. The complications that occurred were transient hypotony in three cases, choroidal detachment in two cases, and one case of intraocular hemorrhage. No case of tube extrusion or tube kink was observed. CONCLUSIONS Our data suggests that implantation of the Ahmed tube modified with the PPC via the pars plana is safe and effective in patients with secondary refractory glaucomas.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical Technique: Pars Plana Ahmed Glaucoma Valve Implantation

The pars plana model of the Ahmed Glaucoma Valve (AGV) is inserted into the vitreous cavity through a sclerostomy, and has a specially designed clip anchors that it in place and avoids tube kinking. The tube deliver aqueous from within the eye to the episcleral plate covered by Tenon’s capsule and conjunctiva, which stimulates fibrovascular encapsulation around the plate. This article elucidate...

متن کامل

Pars Plana Ahmed Implantation Combined with 23-gauge Vitrectomy for Refractory Neovascular Glaucoma in Diabetic Retinopathy

PURPOSE To evaluate the efficacy and safety of a pars plana Ahmed valve implantation combined with 23-gauge sutureless vitrectomy in the treatment of patients with medically uncontrolled neovascular glaucoma (NVG) in proliferative diabetic retinopathy (PDR). METHODS The authors retrospectively reviewed the records of 11 consecutive patients with refractory NVG in PDR who underwent a 23-gauge ...

متن کامل

Pars plana Ahmed valve implant and vitrectomy in the management of neovascular glaucoma.

BACKGROUND AND OBJECTIVE To evaluate the efficacy and safety of the pars plana Ahmed glaucoma valve (New World Medical, Inc., Rancho Cucamonga, CA) implant combined with pars plana vitrectomy and panretinal photocoagulation for the management of neovascular glaucoma in patients with vitreous hemorrhage. PATIENTS AND METHODS The records of 18 eyes of 17 consecutive patients with neovascular gl...

متن کامل

A case involving an Ahmed™ glaucoma valve transferred from the vitreous into the anterior chamber of the eye with a silicone oil tamponade for the treatment of neovascular glaucoma

PURPOSE To report the short-term efficacy and safety of the transfer of an Ahmed(™) glaucoma valve (AGV™) tube from the vitreous into the anterior chamber, in a patient with neovascular glaucoma who had undergone pars plana AGV(™) implantation and ultimately needed a silicone oil tamponade. CASE A 41-year-old male with proliferative diabetic retinopathy in both eyes was referred to us for tre...

متن کامل

Comparison of the Changes in Corneal Endothelial Cells after Pars Plana and Anterior Chamber Ahmed Valve Implant

Purpose. To compare the changes in corneal endothelial cells after pars plana Ahmed glaucoma valve (AGV) implantation with those after the anterior chamber AGV implantation for refractory glaucoma. Methods. The medical records of 18 eyes with pars plana implantation of AGV (ppAGV) were reviewed retrospectively and were compared with 18 eyes with the anterior chamber AGV (acAGV) implant. The pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2010