Quantitative stress-redistribution thallium-201 SPECT using prone imaging: methodologic development and validation.

نویسندگان

  • H Kiat
  • K F Van Train
  • J D Friedman
  • G Germano
  • G Silagan
  • F P Wang
  • J Maddahi
  • F Prigent
  • D S Berman
چکیده

Prone 201Tl myocardial perfusion SPECT has been shown to improve left ventricular inferior wall counts compared to supine imaging, thus minimizing diaphragmatic attenuation. Prone SPECT quantitative normal limits were developed and prospectively applied to 36 patients who had coronary angiography. The prone imaging table used had a cut-out under cardiac area which increased the average myocardial counts by 10.7% compared to prone SPECT through the standard table. Overall specificity and sensitivity were 80% and 93%, respectively. For the right, left circumflex and left anterior descending coronary arteries, the specificities were 94%, 71%, and 94%; and sensitivities were 88%, 89% and 78%, respectively. The normalcy rate in 55 normal patients was 89%. Incidence and the severity of patients motion in 200 prone SPECT studies were compared to 200 supine SPECT studies. Mild and severe motion occurred in 12% and 4% of the supine studies and in only 3.5% and none of the prone studies, respectively. When compared to supine SPECT, prone SPECT had higher (p less than 0.01) regional counts/pixel in the inferior wall and septum, but required an average increase of 2.9 +/- 1.0 cm in camera to chest wall distance and resulted in a reduction of total myocardial counts. Prone SPECT provides an alternative approach for patients who cannot tolerate supine imaging. It should be considered when inferior wall defects on supine imaging pose a diagnostic dilemma and when motion on supine imaging necessitates repeat acquisition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thallium-201 for assessment of myocardial viability: quantitative comparison of 24-hour redistribution imaging with imaging after reinjection at rest.

Redistribution thallium-201 imaging 2 to 4 h after exercise may be incomplete and therefore may be inadequate to fully assess myocardial variability. Late redistribution imaging 24 h after exercise has been proposed to overcome this limitation of thallium stress imaging. However, because of poor count density the image quality on these studies is often suboptimal. In the present study the diagn...

متن کامل

Comparison of glucose-insulin-thallium-201 infusion single photon emission computed tomography (SPECT), stress-redistribution-reinjection thallium-201 SPECT and low dose dobutamine echocardiography for prediction of reversible dysfunction.

The usefulness of glucose-insulin-thallium-201 (GI-Tl) infusion single photon emission computed tomography (SPECT) in predicting reversible dysfunction has not been evaluated, so the present study recruited 20 patients with regional ischemic dysfunction for investigation. All patients underwent GI-Tl SPECT, post-stress Tl reinjection imaging and low dose dobutamine echocardiography. The diagnos...

متن کامل

Repeatability and Reproducibility of Thallium-201 Gated SPECT for the Measurement of Left Ventricular Function

Received 10/11/2004; revised 11/8/2004; accepted 11/12/2004. For correspondence or reprints contact: Guang-Uei Hung, M.D., Department of Nuclear Medicine, Changhua Christian Hospital, 135 Nan-Shiao Street, Changhua 500, Taiwan. Tel: (886)4-7238595 ext. 3091, Fax: (886)4-7232942, E-mail: [email protected] Background: Gated myocardial perfusion single photon emission computed tomography (SPECT) h...

متن کامل

Thallium-201 myocardial SPECT in a patient with mirror-image dextrocardia and left bundle branch block.

A 53-year-old male patient with a previous diagnosis of situs inversus with mirror-image dextrocardia underwent thallium-201 (Tl-201) stress-redistribution myocardial perfusion single photon emission computed tomography (SPECT). Electrocardiogram (ECG) obtained on right hemithorax revealed constant complete left bundle branch block. Tl-201 stress-redistribution SPECT images revealed abnormal pe...

متن کامل

Slow bolus injection of ribose in the identification of thallium-201 redistribution following combined adenosine/dynamic exercise stress.

AIM A simple stress/redistribution thallium-201 myocardial perfusion imaging protocol may underestimate the degree of thallium redistribution in a defect identified on the stress images. We sought to investigate whether a slow-bolus injection of D-ribose improves the identification of thallium redistribution following combined adenosine/dynamic exercise stress. MATERIALS AND METHODS Fifteen p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 33 8  شماره 

صفحات  -

تاریخ انتشار 1992