Inter- and Intra-observer Variability of a Cervical OPLL Classification Using Reconstructed CT Images
نویسندگان
چکیده
BACKGROUND The lateral radiograph-based system described by Tsuyama is used widely to classify ossification of the posterior longitudinal ligament (OPLL) of the cervical spine. However, OPLL is a complex 3-dimensional (3-D) lesion, not a simple and uniplanar one, which is often difficult to identify on a lateral radiograph. Furthermore, its reliability among spine surgeons has not been investigated. Given the popularity of a reconstructed computed tomography (CT), this study examined the inter- and intra-observer reliability of lateral radiograph-based OPLL classification using that modality. METHODS Five spine surgeons independently reviewed the lateral radiograph, axial CT, 2-D (sagittal) and 3-D reconstructed CT images of 108 OPLL patients on 2 separate occasions. Based on these images, the reviewers classified each OPLL case according to the Tsuyama's system. The kappa values were used to assess the statistical reliability. RESULTS The inter- and intra-observer kappa values were only 0.51 and 0.67 for the lateral radiograph, even in combination with the axial CT images, 0.70 and 0.85 for 2-D CT images, and 0.76 and 0.86 for 3-D CT images, respectively. These kappa values showed a good-to-excellent range for the 2-D and 3-D reconstructed CT images while those of the lateral radiograph indicated a fair range. According to the OPLL types, the inter- and intra-observer reliability was low in the continuous type and high in the circumscribed type on the lateral radiograph. However, the low reliability of the continuous type on lateral radiograph was overcome somewhat using 2-D and 3-D reconstructed CT images. CONCLUSIONS The inter- and intra-observer kappa values were only 0.51 and 0.67 for the lateral radiograph, even in combination with the axial CT images, 0.70 and 0.85 for 2-D CT images, and 0.76 and 0.86 for 3-D CT images, respectively. These kappa values showed a good-to-excellent range for the 2-D and 3-D reconstructed CT images while those of the lateral radiograph indicated a fair range. According to the OPLL types, the inter- and intra-observer reliability was low in the continuous type and high in the circumscribed type on the lateral radiograph. However, the low reliability of the continuous type on lateral radiograph was overcome somewhat using 2-D and 3-D reconstructed CT images.
منابع مشابه
Inter- and Intra-Observer Variability of the Volume of Cervical Ossification of the Posterior Longitudinal Ligament Using Medical Image Processing Software
OBJECTIVE Computed tomography (CT)-based method of three dimensional (3D) analysis (MIMICS®, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of MIMICS® system, and inter- and intra-observer reliability in the measurement of OPLL. METHODS Three neuros...
متن کاملبررسی مقایسهای دقت Cone beam CT، رادیوگرافی داخل دهانی و پروب پریودنتال در اندازهگیری ضایعات استخوانی پریودنتال
Background and Aims: Cone beam computed tomography (CBCT) produces high-quality data about diagnosis and periodontal treatment. To date, there is not enough research regarding periodontal bone measurement using CBCT. The aim of this study was to compare the accuracy of CBCT in measuring periodontal defects to that of intraoral radiography and probing methods.Materials and Methods: Two-hundred a...
متن کاملThe error estimate for contouring the brainstem in radiotherapy of head and neck cancer: a multi-center study from north China.
PURPOSE To analyze the error in contouring the brainstem for patients with head and neck cancer who underwent radiotherapy (RT) based on computed tomography (CT) and magnetic resonance (MR) images. METHODS 20 patients with brain tumor and 17 patients with nasopharyngeal cancer (NPC) were randomly selected. Each patient underwent MR and CT scanning. For each patient, one observer contoured the...
متن کاملTranslation of Methdology used in Human Myocardial Imaging to a Sheep Model of Acute Myocardial Infarction
Background: Pre-clinical investigation of stem cells for repairing damaged myocardium predominantly used rodents, however large animals have cardiac circulation closely resembling the human heart. The aim of this study was to evaluate whether SPECT/CT myocardial perfusion imaging (MPI) could be used for assessing sheep myocardium following an acute myocardial infarction (MI) and response to int...
متن کاملIntraoperative evaluation using mobile computed tomography in anterior cervical decompression with floating method for massive ossification of the posterior longitudinal ligament
BACKGROUND An anterior decompression and fusion (ADF) with the floating method is an effective procedure for treating ossification of the posterior longitudinal ligament (OPLL), allowing a direct decompressive effect on the spinal cord. However, the procedure is skill-intensive, particularly in cases of OPLL with a high canal-occupying ratio. In such cases, there are potential risks for insuffi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2 شماره
صفحات -
تاریخ انتشار 2010