Can the IVIM model be used for renal perfusion imaging?
نویسندگان
چکیده
OBJECTIVE Renal perfusion imaging may provide information about the hemodynamic significance of a renal artery stenosis and could improve noninvasive characterization when combined with angiography. It was proposed previously that diffusion sequences could provide useful perfusion indices based on the intravoxel incoherent motion (IVIM) model. Owing to motion artifacts, diffusion imaging has been restricted to relatively immobile organs like the brain. With the availability of single-shot echo-planar imaging (EPI) our purpose was to evaluate the IVIM model in renal perfusion. METHODS AND MATERIAL Eight volunteers underwent diffusion-sensitive magnetic resonance (MR) imaging of the kidneys using a spin echo (SE) EPI sequence. The diffusion coefficients determined by a linear regression analysis and fits to the IVIM function were calculated. RESULTS AND CONCLUSION Our preliminary experience does not support the possibility of obtaining perfusion information using the IVIM model in the kidneys.
منابع مشابه
A Standardized Parameter-Free Algorithm for Combined Intravoxel Incoherent Motion and Diffusion Kurtosis Analysis of Diffusion Imaging Data.
OBJECTIVES The aims of this study were to implement and systematically evaluate the performance of a new parameter-free segmented algorithm for analysis of diffusion imaging data using a combined intravoxel incoherent motion and diffusion kurtosis imaging (IVIM-DKI) model of spin diffusion in comparison with the simpler intravoxel incoherent motion (IVIM) model. MATERIALS AND METHODS A multis...
متن کاملA two-pool model to describe the IVIM cerebral perfusion.
IntraVoxel Incoherent Motion (IVIM) is a magnetic resonance imaging (MRI) technique capable of measuring perfusion-related parameters. In this manuscript, we show that the mono-exponential model commonly used to process IVIM data might be challenged, especially at short diffusion times. Eleven rat datasets were acquired at 7T using a diffusion-weighted pulsed gradient spin echo sequence with b-...
متن کاملOptimization of intra‐voxel incoherent motion measurement in diffusion‐weighted imaging of breast cancer
PURPOSE The purpose of this study was to optimize intra-voxel incoherent motion (IVIM) measurement in diffusion-weighted imaging (DWI) of breast cancer by separating perfusion and diffusion effects through the determination of an optimal threshold b-value, thus benign and cancerous breast tissues can be accurately differentiated using IVIM-derived diffusion and perfusion parameters. MATERIALS...
متن کاملIn vivo assessment of optimal b-value range for perfusion-insensitive apparent diffusion coefficient imaging.
PURPOSE To assess the optimal b-values range for perfusion-insensitive apparent diffusion coefficient (ADC) imaging of abdominal organs using short-duration DW-MRI acquisitions with currently available ADC estimation methods. METHODS DW-MRI data of 15 subjects were acquired with eight b-values in the range of 5-800 s∕mm(2). The reference-standard, a perfusion insensitive, ADC value (ADC(IVIM)...
متن کاملIntra-voxel incoherent motion MRI of the living human foetus: technique and test–retest repeatability
Background: Our purpose was to test the within-subject (test–retest) reproducibility of the perfusion fraction, diffusion coefficient, and pseudo-diffusion coefficient measurements in various foetus organs and in the placenta based on the intra-voxel incoherent motion (IVIM) principle. Methods: In utero diffusion-weighted IVIM magnetic resonance imaging (MRI) was performed in 15 pregnant women ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of radiology
دوره 26 3 شماره
صفحات -
تاریخ انتشار 1998