The proximal femur--a second look at rational of implant design.

نویسندگان

  • A K Mishra
  • P Chalise
  • R P Singh
  • R K Shah
چکیده

UNLABELLED Twenty five pairs (50 bones) of cadaveric femora were studied morphologically and radio logically using standardized techniques to obtain anthropometric data to evaluate the applicability of internationally designed implant and to generate a database for proximal femur to help in design for future implant if these were found unsuitable. MEASUREMENTS femoral head diameter, femoral neck diameter, diameter of proximal femur, canal width at above and below lesser trochanter and 7.5 cm below lower margin of lesser trochanter, endosteal and extracortical width, isthmus position from lesser trochanter, femoral neck anteversion, neck shaft angle and intramedullary axis of femur. The mean +/- SD of these values were calculated. These values were compared with those reported in the literature for Hong Kong Chinese, Caucasians and were found to be different. The implant designed for western population should be used judiciously and facture implant designed should be specific for (ours) bones. We found the pyriformis fossa is usually not in line with the intramedullary axis. Thus antegrade itramedullary nailing portal should be anterior and lateral to pyriformis fossa.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions

Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...

متن کامل

Analysis of stress distribution around total hip stems custom-designed for the standardized Asian femur configuration

In total hip replacement (THR), bone resorption related to the foreign body reaction around the implant causes bonding failure at the bone-prosthesis interface and adversely affects the function and longevity of femoral implants. Stress shielding is thought to be one of the possible biomechanical factors that causes bone resorption, and is related to prosthesis design. We therefore investigated...

متن کامل

Bone density study of the proximal femur after hip arthroplasty with porous-coated implants

Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...

متن کامل

Revision of failed knee replacements using fixed-axis hinges.

Forty failed hinged arthroplasties of the knee were revised by the insertion of another hinged implant. In 14 cases the prosthesis used at the revision operation was similar to the primary implant; in 26, a hinge with an elongated femoral stem was used, usually replacing part of the femoral shaft. In seven of these knees an elongated tibial stem was also required, though the tibial shaft was re...

متن کامل

Effects of Hip Geometry on Fracture Patterns of Proximal Femur

  Background: Some studies have previously shown that geometry of proximal femur can affect the probability of fracture and type of fracture. It happens since the geometry of the proximal femur determines how a force is applied to its different parts. In this study, we have compared proximal femur’s geometric characteristics in femoral neck (FNF), intertrochanteric (ITF) and Subtrochanteric (ST...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nepal Medical College journal : NMCJ

دوره 11 4  شماره 

صفحات  -

تاریخ انتشار 2009