Encoding of EEG in MR images
نویسندگان
چکیده
Introduction: It was shown in [1] that electrophysiology and other non-MR signals can be measured by MR equipment after modulation to frequencies close to those of the MR-signals. After wireless transmission to the scanner, MR and and non-MR signals were recorded together. The technique is somewhat similar to the "mag stripe" technique used for encoding soundtracks in movies: The signals are encoded in the oversampled region just outside the field-of-view. Here we demonstrate 6 channel simultaneous ECG, EOG and alpha-EEG, all recorded by the scanner during fast echo planar imaging at 3 tesla.
منابع مشابه
Simultaneous trimodal PET-MR-EEG imaging: Do EEG caps generate artefacts in PET images?
Trimodal simultaneous acquisition of positron emission tomography (PET), magnetic resonance imaging (MRI), and electroencephalography (EEG) has become feasible due to the development of hybrid PET-MR scanners. To capture the temporal dynamics of neuronal activation on a millisecond-by-millisecond basis, an EEG system is appended to the quantitative high resolution PET-MR imaging modality alread...
متن کاملGenerating the synthetic CT (sCT) and synthetic MR (sMR: sT1w/sT2w) images of the brain using atlas based method
Introduction: Radiation therapy planning (RTP) is one of the clinical applications in which both CT scan and MRI are used. MR and CT images are applied to determine the target volume and calculation of dose distribution, respectively. In addition, using two imaging modalities increases the department workload and cost. In this study, an algorithm was presented to create synthet...
متن کاملGenerating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method
Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...
متن کاملAutomatic Marker Recognition on MR Images for EEG Electrode Localization
Images for EEG Electrode Localization Gert Van Hoey1;2, Bart Vanrumste1;2, Rik Van de Walle1;3, Paul Boon2, Ignace Lemahieu1 1 University of Ghent, ELIS Department, 2 University Hospital Ghent, Department of Neurology, 3 University Hospital Ghent, MR Department, Sint-Pietersnieuwstraat 41, B-9000 Ghent, Belgium tel. +32 9 240 45 47 fax. +32 9 240 49 71 [email protected] Abstract|The electr...
متن کاملComparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کامل