Asymmetric appearance of intracranial vessels on routine spin-echo MR images: a pulse sequence-dependent phenomenon.
نویسندگان
چکیده
PURPOSE To determine the cause of right to left signal intensity differences arising from intracranial vessels during routine spin-echo axial MR imaging of the head. METHODS AND RESULTS Using a normal imaging sequence in which the default directions of the frequency and phase axes were horizontal and vertical, respectively, differences in signal intensity arising from the vertebral arteries were observed in a healthy subject. With the exchange of the frequency and phase axes relative to the normal sequence, no signal intensity differences between the vertebral arteries were recognized. Other pulse sequence modifications, ie, the use of motion-compensating gradients and the reversed polarity of the frequency-encoding gradient, also resulted in variable appearances of the vertebral arteries, indicating that the right-to-left signal asymmetry of the vertebral arteries observed on the normal spin-echo image results from a pulse sequence dependent phenomenon. CONCLUSIONS Frequency-encoding and slice-selection gradients both produce motion-induced phase shifts. These phase shifts depend on the angle between the direction of flow and that of the effective vector sum of these gradients. The asymmetric appearance of the vertebral arteries during normal spin-echo imaging was found to result from the angle dependence of motion-induced phase shifts. Awareness of this artifactual phenomenon is important to avoid confusing it with conditions such as stenosis/occlusion, dissection, or slow flow.
منابع مشابه
The role of ferritin and hemosiderin in the MR appearance of cerebral hemorrhage: a histopathologic biochemical study in rats.
A rat model of cerebral hemorrhage using stereotaxic injection of blood into the right basal ganglia was developed to investigate the influence of iron metabolism on the appearance of cerebral hemorrhage on MR images. Images of in vitro fixed brain sections stained specifically for different iron-storage substances, ferritin and hemosiderin, created by digitization of the pathology sections usi...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملGeometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes
Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...
متن کاملCalcified intracranial lesions: detection with gradient-echo-acquisition rapid MR imaging.
Seventeen patients with partially calcified intracranial lesions, as documented by CT, were evaluated with MR imaging at 1.5 T. All patients were imaged with both conventional spin-echo techniques and reduced flip-angle gradient-echo-acquisition (GEA) sequences, during which a signal is acquired in the absence of a 180 degrees radiofrequency pulse. GEA parameters were implemented so that T2* ef...
متن کاملT1-weighted three-dimensional magnetization transfer MR of the brain: improved lesion contrast enhancement.
PURPOSE We developed and evaluated clinically T1-weighted three-dimensional gradient-echo magnetization transfer (MT) sequences for contrast-enhanced MR imaging of the brain. METHODS A short-repetition-time, radio frequency-spoiled, 3-D sequence was developed with a 10-millisecond MT pulse at high MT power and narrow MT pulse-frequency offset, and the enhancing lesion-to-normal white matter b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 13 4 شماره
صفحات -
تاریخ انتشار 1992