Reply to comment by De Bernardo and Rosa on "Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus".
نویسندگان
چکیده
Corresponding author at: Department of Medicine and Surgery, University of Salerno, Via Salvador Allende, 84081 Baronissi (SA), Italy. E-mail address: [email protected] (M. De Bernardo). https://doi.org/10.1016/j.optom.2017.10.001 1888-4296/ © 2017 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-ncnd/4.0/).
منابع مشابه
Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus
PURPOSE To compare the intraocular pressure (IOP) measurements obtained with the rebound tonometry (RT), dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in keratoconic corneas and to investigate the effects of central corneal thickness (CCT) and corneal radius of curvature (CR) on IOP measurements. METHODS Sixty-three eyes of 63 keratoconus patients were enrolled in t...
متن کاملCorrelation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.
PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...
متن کاملDynamic contour tonometry and goldman applanation tonometry in eyes with keratoconus.
PURPOSE The dynamic contour tonometer is a nonapplanation contact tonometer designed to be largely independent of the structural properties of the cornea. Theoretically, it may measure intraocular pressure most accurately in abnormally thinner corneas. This study compares intraocular pressure measurements by dynamic contour tonometry with Goldman applanation tonometry in eyes with normal cornea...
متن کاملDynamic contour tonometry versus Goldmann applanation tonometry: challenging the gold standard
متن کامل
Dynamic Contour Tonometry, Tono-Pen XL®, and Goldmann Applanation Tonometry in Comparison to Intracameral Intraocular Pressure (IOP) Measurements in Patients with Corneal Pathologies
Unspecified Posted at the Zurich Open Repository and Archive, University of Zurich ZORA URL: http://doi.org/10.5167/uzh-101903 Published Version Originally published at: Neuburger, M; Grosswendt, J; Lautebach, S; Maier, P; Birnbaum, F; Böhringer, D; Funk, J; Jordan, J F; Reinhard, T (2014). Dynamic Contour Tonometry, Tono-Pen XL®, and Goldmann Applanation Tonometry in Comparison to Intracameral...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of optometry
دوره 11 2 شماره
صفحات -
تاریخ انتشار 2018