Field calibration of low density polyethylene passive samplers for gaseous POPs.
نویسندگان
چکیده
A field calibration study of low density polyethylene (LDPE) for measuring atmospheric concentrations of persistent organic pollutants (POPs) was performed in East Providence (RI), USA. LDPE samplers were collected after 3, 7, 10, 14, 17 and 21 days of exposure along with samples from a co-deployed high volume sampler. Uptake kinetics of POPs by LDPEs were confirmed both by using an uptake study over time and the inclusion of performance reference compounds (PRCs). Results indicated that only POPs with log sampler-air partitioning coefficient (KPE-A) ≤ 7.6 were approaching equilibrium by the end of the deployment period, whereas all the other POPs were still in the linear uptake rate. Sampling rates (1.0-80 m(3) per day) were higher for some POPs when compared to literature values possibly due to the open sampler housing design used. Derived KPE-As for the detected POPs in field calibration study were correlated against the compounds' octanol-air partitioning coefficients (log KOA): [log KPE-A = 0.88 ± 0.02 × log KOA + 0.40 ± 0.21 (R(2) = 0.96; n = 59; SE = 0.23)], and their subcooled liquid vapour pressures (log PL/Pa): [log KPE-A = -0.82 ± 0.02 × log PL + 6.22 ± 0.05 (R(2) = 0.96; n = 59; SE = 0.22)] to predict values for all POPs. PL was generally found to be a better predictor of KPE-A for all POPs.
منابع مشابه
Measurement of cyclic volatile methylsiloxanes in the aquatic environment 1 using low - density polyethylene passive sampling devices using an in - field 2 calibration study – challenges and guidance 3
14 Cyclic volatile methylsiloxanes (cVMS) are used in personal care products and are 15 hydrophobic, volatile and persistent. Their environmental water concentrations are low and 16 are difficult to detect using conventional sampling methods. This study shows the potential of 17 passive sampling for cVMS. We used low-density polyethylene (LDPE) samplers and in-field 18 calibration methods for o...
متن کاملUse of passive sampling devices for monitoring and compliance checking of POP concentrations in water.
BACKGROUND The state of the art of passive water sampling of (nonpolar) organic contaminants is presented. Its suitability for regulatory monitoring is discussed, with an emphasis on the information yielded by passive sampling devices (PSDs), their relevance and associated uncertainties. Almost all persistent organic pollutants (POPs) targeted by the Stockholm Convention are nonpolar or weakly ...
متن کاملSpatial trends, sources, and air-water exchange of organochlorine pesticides in the Great Lakes basin using low density polyethylene passive samplers.
Polyethylene passive samplers were deployed during summer and fall of 2011 in the lower Great Lakes to assess the spatial distribution and sources of gaseous and freely dissolved organochlorine pesticides (OCPs) and their air-water exchange. Average gaseous OCP concentrations ranged from nondetect to 133 pg/m(3). Gaseous concentrations of hexachlorobenzene, dieldrin, and chlordanes were signifi...
متن کاملDepth Profiles of Persistent Organic Pollutants in the North and Tropical Atlantic Ocean.
Little is known of the distribution of persistent organic pollutants (POPs) in the deep ocean. Polyethylene passive samplers were used to detect the vertical distribution of truly dissolved POPs at two sites in the Atlantic Ocean. Samplers were deployed at five depths covering 26-2535 m in the northern Atlantic and Tropical Atlantic, in approximately one year deployments. Samplers of different ...
متن کاملMonitoring polynuclear aromatic hydrocarbons in aqueous environments with passive low-density polyethylene membrane devices.
Low-density polyethylene membranes, typically filled with triolein, have been previously deployed as passive environmental samplers designed to accumulate nonpolar hydrophobic chemicals from water, sediments, and air. Hydrocarbons in such samplers, known as semipermeable membrane devices (SPMDs), diffuse through pores in the membranes and are trapped in the central hydrocarbon matrix, mimicking...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Environmental science. Processes & impacts
دوره 16 3 شماره
صفحات -
تاریخ انتشار 2014