Does asthma-like increased breathing load influence impedance pneumography signal?
نویسندگان
چکیده
Asthma is a chronic disease characterized by recurrent attacks of breathlessness and wheezing. During an asthma attack, a bronchospasm occurs. In order to overcome increased resistance of airways forced breathing is necessary. It affects the intrapleural pressure, blood volume within the thoracic cavity and therefore it may affect also impedance pneumography signal. We tried to imitate asthma-like conditions by increasing breathing load in to find out, whether it influences impedance pneumography signal. Forced breathing was performed as a respiration through adjustable respiratory loads. The study subjects breathed through 4, 7 and 10 cmH2O*s/liter breathing loads, at 6 and 12 breathes per minute rates. A calibration coefficient between tidal volume and impedance pneumography and the effect of breathing load on cardiac component of impedance pneumography signal were determined. We found that forced respiration did not significantly affect the impedance pneumography signal, thus it seems unlikely that asthma-like bronchospasms will disturb calibration of the impedance pneumography signal. Thus it is likely, that this technique can reliably measure respiratory parameters during long-term ambulatory monitoring of patients with asthma.
منابع مشابه
Impedance pneumography: noise as signal in impedance cardiography.
Thoracic impedance is modulated by events within the respiratory cycle, which represents a source of "noise" in impedance cardiography. Respiration itself, however, is a physiological rhythm of interest to psychophysiologists. We report here methods and validation for deriving impedance pneumographic measures of respiration from impedance cardiography signals, based on standard tetrapolar band ...
متن کاملTidal flow variability measured by impedance pneumography relates to childhood asthma risk.
Lung function variability is a fundamental feature of asthma but has been difficult to quantify in children due to methodological limitations. We assessed the feasibility and clinical implications of overnight flow variability measurement at home using impedance pneumography in young children.44 children aged 3-7 years with recurrent or persistent lower airway symptoms were recruited. Patients ...
متن کاملComparison of Acoustic Respiration Rate, Impedance Pneumography and Capnometry Monitors for Respiration Rate Accuracy and Apnea Detection during GI Endoscopy Anesthesia
Study Objective: To assess the accuracy of respiration rate measurements and the ability to detect apnea by capnometry, impedance pneumography and a new method, acoustic respiration rate monitoring, in anesthetized patients undergoing gastrointestinal endoscopy procedures. Design: Prospective observational study. Setting: Endoscopy procedures laboratory. Patients: 98 patients scheduled for uppe...
متن کاملRespiration Rate Measurement Based on Impedance Pneumography
This document discusses the use of impedance pneumography as a technique to measure respiration rate. The generation of high-frequency ac current source is described, and the issues related to delay in modulated signal and finite transition times of carriers are addressed. The report also includes descriptions of potential implementations of a respiration rate measurement system using the ADS12...
متن کاملRespiratory Monitoring: Advantages of Inductive Plethysmography over Impedance Pneumography
Inductive plethysmography and impedance pneumography are two non-invasive technologies for measuring respiratory function. The following report describes the advantages of inductive plethysmography, which include greater accuracy and sensitivity; the ability to assess thoracoabdominal coordination; and the minimization of motion artifact. Together, these properties make inductive plethysmograph...
متن کامل