Prediction of Both Electrical and Mechanical Reverse Remodeling on Acute Electrocardiogram Changes After Cardiac Resynchronization Therapy.

نویسندگان

  • Chien-Ming Cheng
  • Chieh-Shou Su
  • Pesus Chou
  • Ying-Chieh Liao
  • Chi-Yen Wang
  • Jian-Rong Zhang
  • Yu-Cheng Hsieh
  • Tsu-Juey Wu
  • Yu-Wei Chen
  • Chi-Jen Weng
  • Keng-Hao Chang
  • Weihua Zhou
  • Guang-Uei Hung
  • Jin-Long Huang
  • Kenichi Nakajima
چکیده

BACKGROUND The development of both electrical reverse remodeling and mechanical reverse remodeling (ERR+MRR) after cardiac resynchronization therapy (CRT) implantation could reduce the incidence of lethal arrhythmia, hence the prediction of ERR+MRR is clinically important.Methods and Results:Eighty-three patients (54 male; 67±12 years old) with CRT >6 months were enrolled. ERR was defined as baseline intrinsic QRS duration (iQRSd) shortening ≥10 ms in lead II on ECG after CRT, and MRR as improvement in LVEF ≥25% on echocardiography after CRT. Acute ECG changes were measured by comparing the pre-implant and immediate post-implant ECG. Ventricular arrhythmia episodes, including ventricular tachycardia and ventricular fibrillation, detected by the implanted device were recorded. Patients were classified as ERR only (n=12), MRR only (n=23), ERR+MRR (n=26), or non-responder (ERR- & MRR-, n=22). On multivariate regression analysis, difference between baseline intrinsic QRS and paced QRS duration (∆QRSd) >35 ms was a significant predictor of ERR+MRR (sensitivity, 68%; specificity, 64%; AUC, 0.7; P=0.003), and paced QTc >443 ms was a negative predictor of ERR+MRR (sensitivity, 78%; specificity, 60%; AUC, 0.7; P=0.002). On Cox proportional hazard modeling, ERR+MRR may reduce risk of ventricular arrhythma around 70% compared with non-responder (HR, 0.29; 95% CI: 0.13-0.65). CONCLUSIONS Acute ECG changes after CRT were useful predictors of ERR+MRR. ERR+MRR was also a protective factor for ventricular arrhythmia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double mechanical prosthesis, correct international normalized ratio, and giant atrial mass.

Schalij MJ, Bax JJ. Optimal left ventricular lead position predicts reverse remodeling and survival after cardiac resynchronization therapy. J Am Coll Cardiol 2008;52: 1402–1409. 28. Yu Y, Kramer A, Spinelli J, Ding J, Hoersch W, Auricchio A. Biventricular mechanical asynchrony predicts hemodynamic effect of uniand biventricular pacing. Am J Physiol Heart Circ Physiol 2003;285:H2788–H2796. 29. ...

متن کامل

Integration of mechanical, structural and electrical imaging to understand response to cardiac resynchronization therapy.

INTRODUCTION AND OBJECTIVES There is extensive controversy exists on whether cardiac resynchronization therapy corrects electrical or mechanical asynchrony. The aim of this study was to determine if there is a correlation between electrical and mechanical sequences and if myocardial scar has any relevant impact. METHODS Six patients with normal left ventricular function and 12 patients with l...

متن کامل

Improvement in left ventricular intrinsic dyssynchrony with cardiac resynchronization therapy

OBJECTIVE Cardiac resynchronization therapy (CRT) has been shown to induce a structural and electrical remodeling; the data on whether left ventricle (LV) reverse remodeling is associated with restitution of intrinsic contraction pattern are unknown. In this study, we investigated the presence of improvement in left ventricular intrinsic dyssynchrony in patients with CRT. METHODS A total of 4...

متن کامل

Arrhythmia/Electrophysiology Analysis of Ventricular Activation Using Surface Electrocardiography to Predict Left Ventricular Reverse Volumetric Remodeling During Cardiac Resynchronization Therapy

Background—Cardiac resynchronization therapy for heart failure with left bundle branch block reduces left ventricular (LV) conduction delay, contraction asynchrony, and LV end-systolic volume (“reverse remodeling”). Up to one third of patients do not improve, and the electric requirements for reverse remodeling are unclear. We hypothesized that reverse remodeling is predicted by the left bundle...

متن کامل

Analysis of ventricular activation using surface electrocardiography to predict left ventricular reverse volumetric remodeling during cardiac resynchronization therapy.

BACKGROUND Cardiac resynchronization therapy for heart failure with left bundle branch block reduces left ventricular (LV) conduction delay, contraction asynchrony, and LV end-systolic volume ("reverse remodeling"). Up to one third of patients do not improve, and the electric requirements for reverse remodeling are unclear. We hypothesized that reverse remodeling is predicted by the left bundle...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 81 9  شماره 

صفحات  -

تاریخ انتشار 2017