Investigation on the Potential Rise and Currents in Insulated Mast Scheme with Single Tower During Stroke Interception
نویسنده
چکیده
The insulated mast scheme for the lightning protection system can be found in a few practical designs. Many advantages over conventional protection system are some times envisaged. However, the technical literature on the analysis of such schemes and further quantification of their protection efficacy is rather scarce. As a first step to address this problem, the present work is taken up and the potential rise at the top and ground end currents in insulating mast scheme with single tower is investigated for several tower heights and pertinent values of other parameters. The quantities that are investigated are the potential difference across the insulation and ground end currents for both tower and the ground wires. Quantifications are carried out for the relevant range of stroke current front times. The influence of number of ground wires, their earthing location and to a limited extent, the length of the insulating support have been ascertained. Some relevant discussion on insulation strength is made. These findings are quite novel and aid in quantification of the practical efficacy of the insulated mast scheme. The level of induction to the support tower and possible flashover to the same are not in favour of this scheme.
منابع مشابه
Analysis of effective factors on transient ground potential rise in gas insulated substations
This study presents the manner in which transient modeling concepts, which are fully analyzed in the referred standards, are implemented, for the purpose of evaluating the Transient Ground Potential Rise (TGPR). This is a phenomenon of 10–100kV voltages with up to 10μs duration on the grounded enclosure of Gas Insulated Substations (GIS), which may cause concern for personnel safety and problem...
متن کاملAnalysis of effective factors on transient ground potential rise in gas insulated substations
This study presents the manner in which transient modeling concepts, which are fully analyzed in the referred standards, are implemented, for the purpose of evaluating the Transient Ground Potential Rise (TGPR). This is a phenomenon of 10–100kV voltages with up to 10µs duration on the grounded enclosure of Gas Insulated Substations (GIS), which may cause concern for personnel safety and pro...
متن کاملExperimental Investigation of Impulse Characteristics of Transmission Line Tower Footings
Understanding the impulse response of tower grounding systems is a key factor in the determination of the lightning performance of transmission lines and the safety voltages near high voltage towers. This paper reports the results of an experimental study on the impulse characteristics of full-scale transmission line tower footings. The ground potential distribution both at the ground surface a...
متن کاملInvestigation of Vertical Wind Shear Characteristics Using 50m Meteorological Tower Data
Wind measurement is important for estimating wind energy potential, but it is relatively cost-intensive and often conducted at a narrow height from the ground level. The typical range of most turbine hub heights is from 30-50 m or even higher. Extrapolation on wind data thus becomes necessary to estimate the wind speed at different heights. Doing so requires the essential understanding of wind ...
متن کاملInvestigation of the Gravel Filters and Plastic Mulch Effects in Improving Soil Infiltration and Moisture Storage in Rainwater Harvesting Systems in Steep Lands
In this study, the possibility of using a combination of gravel filters with plastic cover to increase water infiltration and soil moisture storage in rainwater catchment systems was investigated. For this purpose, five treatments (with three replications) including control treatment, vegetation removal with filter, vegetation removal without filter, semi-insulated system with filter, an...
متن کامل