X-ray spectrometer with a low-cost SiC photodiode

نویسندگان

  • S. Zhao
  • G. Lioliou
  • A. M. Barnett
چکیده

A low-cost Commercial-Off-The-Shelf (COTS) 4H-SiC 0.06 mm2 UV p-n photodiode was coupled to a low-noise charge-sensitive preamplifier and used as photon counting X-ray spectrometer. The photodiode/spectrometer was investigated at X-ray energies from 4.95 keV to 21.17 keV: a Mo cathode X-ray tube was used to fluoresce eight high-purity metal foils to produce characteristic X-ray emission lines which were used to characterise the instrument. The energy resolution (full width at half maximum, FWHM) of the spectrometer was found to be 1.6 keV to 1.8 keV, across the energy range. The energy linearity of the detector/spectrometer (i.e. the detector’s charge output per photon as a function of incident photon energy across the 4.95 keV to 21.17 keV energy range), as well as the count rate linearity of the detector/spectrometer (i.e. number of detected photons as a function of photon fluence at a specific energy) were investigated. The energy linearity of the detector/spectrometer was linear with an error <± 0.7 %; the count rate linearity of the detector/spectrometer was linear with an error <± 2 %. The use of COTS SiC photodiodes as detectors for X-ray spectrometers is attractive for nanosatellite/CubeSat applications (including solar flare monitoring), and for cost sensitive industrial uses. © 2018 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

امکان سنجی بکارگیری عناصر نیمه هادی از نوع PIN به منظور دزیمتری پرتوهای ایکس تشخیصی

Knowing patient exact dose during radiological activities is considered as one of the main principles to decrease radiation-induced dangers which are not really necessary and affect a great deal of people. In this respect, in recent years many extensive studies have been done on types of photodiodes and production of X-ray detectors using semiconductor elements. Since these elements are not ver...

متن کامل

Soft X-ray Emission from Post-Pulse Expanding Laser-Produced Plasmas

A new diagnostic spectrometer has been developed at the Naval Research Laboratory (NRL) to measure the time resolved absolute intensity of radiation emitted by the Nike laser irradiated targets. The spectrometer consists of a dispersive transmission grating of 2500 lines/mm or 5000 lines/mm and a detection system consisting of an absolutely calibrated Si photodiode array and a CCD camera. In th...

متن کامل

The effect of doping Graphene Quantum Dots with K, B, N, and Cl on its emitted spectrum

In this work, the effect of doping Graphene Quantum Dots (GQDs) on their emission spectra has been studied. First, graphene has been deposited on SiC substrate by using sublimation method. Second, doped-GQDs have been distributed on the surface of graphene via drop casting. The structure of the samples have been studied and characterized by X-ray diffraction (XRD), Scanning Electron Microscopy ...

متن کامل

A liquid-helium cooled large-area silicon PIN photodiode x-ray detector

An x-ray detector using a liquid-helium cooled large-area silicon PIN photodiode has been developed along with a tailor-made charge sensitive preamplifier whose firststage JFET has been cooled. The operating temperature of the JFET has been varied separately and optimized. The xand γ-ray energy spectra for an Am source have been measured with the photodiode operated at 13 K. An energy resolutio...

متن کامل

Thermal effects in the size distribution of SiC nanodots on Si(111)

We have used scanning tunneling microscopy (STM), Auger electron spectroscopy (AES) and X-ray Photoelectron spectroscopy (XPS) to investigate the formation of nanoscopic structures on Si(111), from wafers with a high bulk C concentration. The samples were prepared by long time thermal annealing of the silicon samples, followed by a high temperature flash in ultrahigh vacuum. An increased surfac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2018