Validation of QB stress test as a useful tool in the detection of native arteriovenous fistula stenosis: results after 22 months of follow-up.

نویسندگان

  • Giuseppe Bonforte
  • Daniela Pogliani
  • Silvia Brenna
  • Daniela Martinelli
  • Luca Emilio Bernardi
  • Marco D'Amico
  • Stefano Mangano
  • Emanuela Rossi
  • Simonetta Genovesi
  • Carlo Grillo
چکیده

BACKGROUND Access flow (QA) surveillance is the best method recommended for early stenosis detection, but in native arteriovenous fistula (AVF), the literature is conflicting about the real need for monthly monitoring of QA, as suggested by the K-DOQI Guidelines. METHODS From 1 January 2006 to 31 October 2007 (mean 18.0 +/- 4.9 months), we prospectively followed up 224 patients with monthly AVF monitoring by means of clinical examination and QB stress test (QBST). Suspected malfunctioning AVFs were referred to ultrasound dilution technique (UDT) and imaging techniques (Doppler ultrasonography, angiography), with eventually further percutaneous angioplasty (PTA) or surgical revision. RESULTS We observed a good correlation between QBST and QA measurement obtained by the UDT. Patients with positive QBST had a lower QA than negative QBST subjects (433 +/- 203 vs 1168 +/- 681 ml/min, P < 0.0001). Fifty-four out of 224 (24%) patients were selected for possibly malfunctioning AVF. We found no stenosis in 13 out of 54 (24%) patients, inflow stenosis in 29 out of 54 (54%) patients and outflow stenosis in 12 out of 54 (22%) patients. The QBST positive predictive value for inflow stenosis was 76.3%. The interventional radiologist performed 38 PTA procedures in 33 patients (11 PTA per 100 patient-years) and we surgically created 13 new AVF (3.7 per 100 patient-years). Only five thrombosis episodes occurred in five patients during the follow-up (1.5 thromboses per 100 patient-years). CONCLUSIONS QBST is a simple, low-cost, not time-consuming test, able to select, together with clinical evaluation, malfunctioning AVF with stenosis located specifically in the inflow tract. Our follow-up data demonstrated that it is possible to achieve a low AVF thrombosis rate by adding QBST in an AVF monitoring program, thus reducing the surveillance burden.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The experience use of drug-coated & non drug-coated balloons in arteriovenous fistula at a six months period: brief report

Background: The ineffectiveness of hemodialysis fistulas causes high costs and increases mortality and morbidity rates. The efficacy of drug-coated balloon and nondrug-coated balloon in dysfunctional arteriovenous Fistula was evaluated over six month period. Methods: In this randomized clinical trial, a total of a total of 50 hemodialysis patients who referred to Imam Reza Hospital in Kermansh...

متن کامل

A Comparative Study on the Effects of Acupressure at SP6 and ST36 Acupoints on the Pain Caused by Fistula Needle Placement in Hemodialysis Patients

Introduction: Hemodialysis is one of the most common treatment methods in kidney patients. To do this, repeated insertion of the needle into the vessel is necessary. Patients treated with hemodialysis are exposed to stress and pain caused by perforation of their arteriovenous fistula about 300 times a year. More than 1/5 of hemodialysis patients express this pain as unbearable. This study aims ...

متن کامل

Effect of Cryotherapyon Pain Following Fistula Puncture in Patients Undergoing Hemodialysis

Background and Objectives: Patients undergoing hemodialysis are exposed to stress and pain due to approximately 300 punctures per year they receive for their arteriovenous fistula. Alleviation of the pain can improve acceptance of the procedure and quality of life among the patients. This study aimed to assess the effect of cryotherapy on arteriovenous fistula puncture pain among patients uderg...

متن کامل

Percutaneous transluminal angioplasty in the treatment of stenosis of arteriovenous fistulae for hemodialysis

BACKGROUND Thrombosis following stenosis of arteriovenous fistulae resulting in the loss of vascular access for hemodialysis is an important complication in patients with chronic renal failure. Percutaneous transluminal angioplasty is being used more frequently in the treatment of stenosis aiming at increasing the patency of arteriovenous fistulae. OBJECTIVE To evaluate the primary patency of...

متن کامل

یورتروپلاستی به روش TIP در بیماران مبتلا به هیپوسپادیاس بیمارستان بوعلی سینا ساری سال 83-1378

Background and purpose : Hypospadias is a common congenital anomaly of urogenital system. In spite of different techniques for treatment of hypospadias and complications such as fistula after operation, most surgeons are keen of doing operations with the least complications and best results. TIP urethroplasty has been introduced for hypospadias repair in recent years and is becoming popular f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 2010