Chondrosarcoma from the sternum: Reconstruction with titanium mesh and a transverse rectus abdominis myocutaneous flap after subtotal sternal excision
نویسندگان
چکیده
BACKGROUND Chondrosarcoma arising from the sternum is extremely rare and is often untreatable. Removal of the sternum for malignant tumor results in large defects in bone and soft tissue, causing deformity and paradoxical movement of the chest wall and making subsequent repair of the thorax very important. We report a very rare patient with a chondrosarcoma of the sternum who underwent case chest wall resection, followed by reconstruction using a titanium mesh covered with a transverse rectus abdominis myocutaneous (TRAM) flap. CASE REPORT A 63-year-old man was referred to our hospital with progressively enlarged swelling of his anterior chest wall. Physical examination showed a 2.5×2.0 cm mass fixed to the sternum, which was diagnosed as a chondrosarcoma based on clinical findings, imaging characteristics and incision biopsy results. The patient underwent a subtotal sternal and chest wall resection to remove the tumor, followed by reconstruction with a titanium mesh and a TRAM flap. There were no complications associated with surgery. CONCLUSIONS We report an extremely rare case of a patient who underwent subtotal sternal resection, followed by reconstruction, for a large chondrosarcoma. The elasticity and rigidity provided by the titanium mesh and the complete coverage of the surgical wound by a TRAM flap suggest that these procedures may be useful in reconstructing large defects in the chest wall.
منابع مشابه
Management of the extensive thoracic defects after deep sternal wound infection with the rectus abdominis myocutaneous flap
Deep sternal wound infection is a severe complication after open heart surgery. According to the different severity and dimensions of the deep sternal wound infection, the treatment method is different. In this study, we aimed to describe our experience with the rectus abdominis myocutaneous flap for large sternal wound management, especially when 1 or 2 internal mammary arteries were absent.Be...
متن کاملThoracoplasty with acrylic plate-marlex mesh combination following near total resection of sternum: a case of chondrosarcoma of sternum.
Removal of the whole sternum for malignant tumours results in a large defect, causing severe deformity and possible paradoxical movements of the chest wall. The reconstruction of the resultant large defect of the chest wall is often complex and difficult. Commonly used materials include rib autograft, steel strus acrylic plate and various synthetic meshes such as Goretex or Marlex mesh, with a ...
متن کاملNew technical approach for the repair of an abdominal wall defect after a transverse rectus abdominis myocutaneous flap: a case report
INTRODUCTION Breast reconstruction with autologous tissue transfer is now a standard operation, but abnormalities of the abdominal wall contour represent a complication which has led surgeons to invent techniques to minimize the morbidity of the donor site. CASE PRESENTATION We report the case of a woman who had bilateral transverse rectus abdominis myocutaneous flap (TRAM-flap) breast recons...
متن کاملUmbilical necrosis post unilateral pedicled transverse rectus abdominis myocutaneous flap.
We report a case of umbilical necrosis after a unilateral pedicled transverse rectus abdominis myocutaneous flap in a patient post mastectomy. This uncommon complication of breast reconstruction is highlighted.
متن کاملOutcome of Management of Local Recurrence after Immediate Transverse Rectus Abdominis Myocutaneous Flap Breast Reconstruction
BACKGROUND No consensus has been reached regarding the outcome of management of local recurrence after transverse rectus abdominis myocutaneous (TRAM) flap breast reconstruction. This study demonstrated the presentation, management, and outcomes of local recurrence after immediate TRAM breast reconstruction. METHODS A comparison was conducted among 1,000 consecutive patients who underwent imm...
متن کامل