In-line Automated Tracking in Cardiac Cine MRI

نویسندگان

  • B. Li
  • Y. Liu
  • B. R. Cowan
  • A. A. Young
چکیده

Introduction: The tracking of anatomical features in cardiac cine MR images facilitates the analysis of myocardial motion. For example, wall thickening is an important clinical index of myocardial function. Non-rigid registration methods allow fast, automatic tracking of image features through a temporal sequence [1]. We implemented an efficient non-rigid registration algorithm on the scanner’s image reconstruction computer to perform in-line calculation of deformation maps. The method was evaluated in a clinical setting by comparing manual wall thickening measurements with the automated tracking results in 36 patients with cardiovascular disease. Methods: A standard SSFP (trueFISP) cardiac cine acquisition sequence was modified to use a custom reconstruction algorithm which included a non-rigid registration feature tracking step after the standard image reconstruction. The method was implemented on a Siemens 1.5T Avanto system (VB15) with a reconstruction computer comprising dual AMD single core Opteron 248 CPUs (2.2 GHz) and 8Gb RAM. The non-rigid registration was performed between successive image frames, in both the forward and backward time directions, using a free-form deformation algorithm, as described previously [1]. A sum of squares objective function was minimized using a non-linear least squares Levenburg-Marquardt (LM) algorithm, incorporating a multi-level coarse to fine optimization, in a 128x128 pixel region of interest in the center of the image. The Siemens ICE environment was used to parallelize the registration to exploit both CPUs. The ACML BLAS library was used for efficient solution of the linear equations resulting at each LM iteration. The final deformation maps between each image pair were stored in the DICOM image headers, so that they could subsequently be used for tracking and wall thickening analysis. The time taken for the in-line non-rigid registration algorithm was recorded in six short axis and three long axis slice acquisitions for single normal volunteer. Imaging parameters were: TR/TE/flip angle: 27.1ms/1.27ms/69deg; iPAT factor 2; segments 9; bandwidth 930 Hz/pixel; FOV 340x276.25mm; image matrix 256x208; slice thickness 6 mm; retrospectively gated with 25 cardiac frames and a breath-hold duration of 12 seconds. Image deformation maps were calculated in-line and compared with a previously validated offline registration procedure [1]. To evaluate the method in the context of wall thickening evaluation, mid-ventricular short axis cines from 36 patients with cardiovascular disease, enrolled in the ONTARGET MRI sub-study [2], were processed with the same registration software. Wall thickening results obtained using the centreline method [3] were averaged over the slice and compared with results obtained from a manual segmentation procedure (guide point modelling using CIM V6.0 [4]). Inter-observer errors were calculated for both manual and automated methods, from contours placed by two independent experienced observers. In the automated method, contours placed at end-diastole by each observer were automatically tracked to endsystole (ES) using the in-line image deformation maps. Results: The time required for the image reconstruction and registration calculation was 10.1 +/1.9 seconds (mean +/std dev, range from 7.4 to 14.1 seconds) per slice. Of this less than 1 second was required for image reconstruction. Deformation maps are shown for the in-line calculation compared with a previously validated off-line calculation [1] in Figure 1. Average wall thickening over the mid-ventricular short axis slice in 36 patients are displayed in Figure 1d at ES for the two observers, showing increased reproducibility with the automatic tracking method. The interobserver errors in wall thickening using the manual method were 1 +/14 % at ES, and -1 +/5 % for the automated method. The errors between automated and manual results were 8 +/13 % at ES for Observer 1 and similar for Observer 2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validating feature tracking MRI for the assessment of strain rate in patients with various hemodyanamic states

Background Myocardial strain rate (SR) is a valuable measurement in assessing myocardial mechanical properties, which can be compared between subjects in the setting of various hemodynamic states. Feature tracking (FT) is a novel method to assess SR off-line on cine images acquired in routine cardiac MRI. In this study we sought to assess SR using the FT method in a group of patients and to val...

متن کامل

Automated cardiac motion estimation from 3D Cine DENSE MRI

Background 3D cine displacement encoding with stimulated echoes (DENSE) directly encodes tissue displacement into MR phase data, providing a comprehensive 3D view of cardiac motion and strain. Unfortunately, 3D cine DENSE motion analysis presently requires manually delineated anatomy. An automated analysis would reduce interobserver variability, improve measurement throughput, and simplify data...

متن کامل

Assessment of cardiac dyssynchrony: a comparison of velocity encoded imaging and feature tracking analysis

Background Cardiac dyssynchrony can be found in up to 99% of patients suffering from chronic heart failure. MRI VENC (velocity encoded imaging), along with TDI, have been shown to accurately assess myocardial dyssynchrony. Long acquisition times of VENC and a high inter-examiner variability of TDI have prohibited a broad clinical application of these modalities thus far. Recently a new method u...

متن کامل

High-Frequency 4-Dimensional Ultrasound (4DUS): A Reliable Method for Assessing Murine Cardiac Function.

In vivo imaging has provided a unique framework for studying pathological progression in various mouse models of cardiac disease. Although conventional short-axis motion-mode (SAX MM) ultrasound and cine magnetic resonance imaging (MRI) are two of the most prevalent strategies used for quantifying cardiac function, there are few notable limitations including imprecision, inaccuracy, and geometr...

متن کامل

Quantitative assessment of LV function and volumes with 3-slice segmentation of cine SSFP short axis images: our experience

Background Cardiac MRI is the gold standard for assessing cardiac function, but requires contour tracing of the left ventricular (LV) myocardium through multiple cine steadystate free precession (SSFP) short axis images. Despite advancements in semi-automated software, contour detection and manual readjustments of multiple slices throughout the cardiac cavity remains a tedious process. Our goal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008