Research Papers Involving the TSI RespiCon Sampler - Application Note ITI-080

نویسندگان

  • Roy Rando
  • Halet Poovey
  • Dinkar Mokadam
  • Joseph Brisolara
چکیده

Six inhalable aerosol samplers were evaluated experimentally as area samplers using monodisperse solid particles with aerodynamic diameters ranging from 5 to 68 mm. Sampler performance and inside particle loss at two test wind speeds (0.55 and 1.1 m/sec) and three wind orientations (0, 90, and 180 degrees) were investigated. The six inhalable aerosol samplers tested were a RESPICONTM sampler, an Institute of Occupational Medicine (IOM), a seven-hole, a conical inhalable sampler, a prototype button sampler, and a closed-face 37-mm cassette. The area sampling performance of the RESPICONTM sampler matched the inhalable convention fairly well. The sampling performances of the other five samplers depended on wind speed, wind direction, and particle size, and they may not be appropriate for area sampling if the wind speeds are greater than 0.5 m/sec.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Research Papers Involving the Tsi Respicontm Sampler

Six inhalable aerosol samplers were evaluated experimentally as area samplers using monodisperse solid particles with aerodynamic diameters ranging from 5 to 68 mm. Sampler performance and inside particle loss at two test wind speeds (0.55 and 1.1 m/sec) and three wind orientations (0, 90, and 180 degrees) were investigated. The six inhalable aerosol samplers tested were a RESPICONTM sampler, a...

متن کامل

Research Papers Involving the TSI DustTrak Aerosol Monitor - Application Note ITI-079

Particulate air pollution, specifically the fine particle fraction (PM2.5), has been associated with increased cardiopulmonary morbidity and mortality in general population studies. Occupational exposure to fine particulate matter can exceed ambient levels by a large factor. Due to increased interest in the health effects of particulate matter, many particle sampling methods have been developed...

متن کامل

Evaluation of six inhalable aerosol samplers.

Six inhalable aerosol samplers were evaluated experimentally as area samplers using monodisperse solid particles with aerodynamic diameters ranging from 5 to 68 microm. Sampler performance and inside particle loss at two test wind speeds (0.55 and 1.1 m/sec) and three wind orientations (0, 90, and 180 degrees) were investigated. The six inhalable aerosol samplers tested were a RespiCon, an Inst...

متن کامل

Assessment of personal direct-reading dust monitors for the measurement of airborne inhalable dust.

The performances of five portable direct-reading dust monitors were investigated in a wind tunnel for a range of industrial dusts and three sizes of aluminium oxide test dust to mainly determine their suitability for measuring the inhalable fraction of airborne dust in workplaces. The instruments tested were Split 2 (SKC Ltd), Sidepak (TSI Inc.), Dataram (Thermo Electron Ltd), PDS-2 (Sibata Sci...

متن کامل

The trend of changes in the Trohic State Index (TSI) in Chitgar Lake during 2013-2019

Lake of the Martyrs of the Persian Gulf (also known as the Chitgar Lake) is located in the north-western of Tehran. The construction of this artificial lake was done by Tehran Municipality was filled water of the Kan River in 2012. TN, TP, SD and Chl-a was used to determine trophic levels. Water sampling was performed by Rotner sampler and the water quality was investigated on 5 stations site d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009