Stereoacuity after small aperture corneal inlay implantation

نویسندگان

  • Steven H Linn
  • David F Skanchy
  • Tyler S Quist
  • Jordan D Desautels
  • Majid Moshirfar
چکیده

PURPOSE The aim of this study was to compare stereoacuity before and after KAMRA corneal inlay implantation for the correction of presbyopia. PATIENTS AND METHODS This is a prospective study of 60 patients who underwent KAMRA inlay implantation. Patients were examined before and 6 months after surgery for stereoacuity, uncorrected distance visual acuity (UDVA), and uncorrected near visual acuity (UNVA). RESULTS The mean stereoacuity before surgery was 29.5±28.1 arcsec (range: 20-200) and at 6 months was 29.8±26.4 arcsec (range: 20-200). The decline in stereoacuity was not statistically significant. At 6 months follow-up, UDVA was 20/25 or better in all 60 patients and UNVA was J2 (20/25) or better in 51 (85%) patients. CONCLUSION There is no significant change in stereoacuity following KAMRA inlay implantation. The KAMRA inlay is a good treatment option for improving near vision in presbyopic patients while preserving stereoacuity and distance vision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term outcomes after monocular corneal inlay implantation for the surgical compensation of presbyopia.

PURPOSE To evaluate long-term outcomes of small-aperture corneal inlay implantation for the surgical compensation of presbyopia. SETTING Paracelsus Medical University, Salzburg, Austria. DESIGN Prospective interventional cohort study. METHODS Monocular implantation of a Kamra small-aperture inlay (model ACI7000) (1.6 mm central aperture) was performed in emmetropic presbyopic eyes. The pr...

متن کامل

Reading performance after implantation of a small-aperture corneal inlay for the surgical correction of presbyopia: Two-year follow-up.

PURPOSE To evaluate the change in reading-performance parameters after implantation of the Kamra small-aperture intracorneal inlay over a 2-year follow-up. SETTING University Eye Clinic, Paracelsus Medical University, Salzburg, Austria. DESIGN Cohort study. METHODS This study comprised naturally emmetropic presbyopic patients. Bilateral reading acuity, reading distance, reading speed, and...

متن کامل

Complete depigmentation of a small aperture corneal inlay implanted for compensation of presbyopia.

We describe a case of late-onset remarkable depigmentation of a small aperture corneal inlay implanted for presbyopia compensation. The patient was a participant in a clinical trial designed to evaluate the safety and efficacy of the AcuFocusTM ACU-10R160, which is a 10 µm-thick polyimide film tinted with an organic dye. Inlay implantation occurred under mechanical microkeratome Lasik flaps set...

متن کامل

Small-aperture corneal inlay in patients with prior radial keratotomy surgeries

This paper describes the 3-month results of two patients who underwent KAMRA™ (AcuFocus, Inc, Irvine, CA, USA) inlay implantation surgery with a history of prior radial keratotomy. The refractive error just before KAMRA inlay implantation was corrected in one patient with a laser-assisted in situ keratomileusis (LASIK) procedure. The post-inlay implantation surgery results showed effective unco...

متن کامل

Impact on stereo-acuity of two presbyopia correction approaches: monovision and small aperture inlay

Some of the different currently applied approaches that correct presbyopia may reduce stereovision. In this work, stereo-acuity was measured for two methods: (1) monovision and (2) small aperture inlay in one eye. When performing the experiment, a prototype of a binocular adaptive optics vision analyzer was employed. The system allowed simultaneous measurement and manipulation of the optics in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017