Fracture length scales in human cortical bone: the necessity of nonlinear fracture models.
نویسندگان
چکیده
Recently published data for fracture in human humeral cortical bone are analyzed using cohesive-zone models to deal with the nonlinear processes of material failure. Such models represent the nonlinear deformation processes involved in fracture by cohesive tractions exerted by the failing material along a fracture process zone, rather than attributing all damage to a process occurring at a single point, as in conventional linear-elastic fracture mechanics (LEFM). The relationship between the tractions and the net displacement discontinuity across the process zone is hypothesized to be a material property for bone. To test this hypothesis, the cohesive law was evaluated by analyzing published load vs. load-point displacement data from one laboratory; the calibrated law was then used to predict similar data taken for a different source of bone using a different specimen geometry in a different laboratory. Further model calculations are presented to illustrate more general characteristics of the nonlinear fracture of bone and to demonstrate in particular that LEFM is not internally consistent for all cases of interest. For example, the fracture toughness of bone deduced via LEFM from test data is not necessarily a material constant, but will take different values for different crack lengths and test configurations. LEFM is valid when the crack is much longer than a certain length scale, representative of the length of the process zone in the cohesive model, which for human cortical bone ranges from 3 to 10mm. Since naturally occurring bones and the specimens used to test them are not much larger than this dimension for most relevant orientations, it is apparent that only nonlinear fracture models can give an internally consistent account of their fracture. The cohesive law is thus a more complete representation of the mechanics of material failure than the single-parameter fracture toughness and may therefore provide a superior measure of bone quality. The analysis of fracture data also requires proper representation of the approximately orthotropic elasticity of the bone specimen; if the specimen is incorrectly assumed to be isotropic, the initial measured compliance cannot be reproduced to within a factor of four and the fracture toughness deduced from the measured work of fracture will be overestimated by approximately 30%.
منابع مشابه
Re-evaluating the toughness of human cortical bone.
Data for fracture in human humeral cortical bone are re-analyzed to assess the validity for this material of linear-elastic fracture mechanics (LEFM), which is the standard method of analyzing toughness and one basis for analyzing clinical data relating to bone quality. A nonlinear fracture model, which is based on representing the damage zone in the bone by a cohesive model, is calibrated agai...
متن کاملEvaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method
longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...
متن کاملThe Multiscale Origins of Fracture Resistance in Human Bone and Its Biological Degradation
Akin to other mineralized tissues, human cortical bone can resist deformation and fracture due to the nature of its hierarchical structure, which spans the molecular to macroscopic length scales. Deformation at the smallest scales, mainly through the composite action of the mineral and collagen, contributes to bone’s strength or intrinsic fracture resistance, while crack-tip shielding mechanism...
متن کاملThe true toughness of human cortical bone measured with realistically short cracks.
Bone is more difficult to break than to split. Although this is well known, and many studies exist on the behaviour of long cracks in bone, there is a need for data on the orientation-dependent crack-growth resistance behaviour of human cortical bone that accurately assesses its toughness at appropriate size scales. Here, we use in situ mechanical testing to examine how physiologically pertinen...
متن کاملAge-related changes in the plasticity and toughness of human cortical bone at multiple length scales.
The structure of human cortical bone evolves over multiple length scales from its basic constituents of collagen and hydroxyapatite at the nanoscale to osteonal structures at near-millimeter dimensions, which all provide the basis for its mechanical properties. To resist fracture, bone's toughness is derived intrinsically through plasticity (e.g., fibrillar sliding) at structural scales typical...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomaterials
دوره 27 9 شماره
صفحات -
تاریخ انتشار 2006