Extraocular Muscles: Variation in Their Anatomy, Length and Cross-sectional Diameter

نویسنده

  • Edward Ridyard
چکیده

Address for Correspondence: Edward Ridyard, 9 The Meadows, Rainhill, Prescot, L35 0PQ, UK. E-Mail: [email protected] Foundation Year 2 doctor, Oxford University Hospitals, Prescot, UK. Background: The extraocular muscles (EOMs) bring about eye movement and studies exist which measure EOM length, cross-sectional diameter and volume. Knowledge of the normal values is crucial for determining when an EOM becomes pathological. The aim of this study was to dissect the orbit and measure the length and crosssectional diameter of the EOMs. Methods and Materials: Eighteen orbits from 9 formalin fixed cadavers (4 male, 5 female), age range 70-95, were dissected. The length of the EOM was measured with a digital caliper, the halfway point of the EOM found and the cross-sectional diameter measured. Length and cross-sectional diameter measurements from the left and right orbits were compared. The correlation between age and EOM length and age and EOM cross-sectional diameter was assessed. The association between gender and EOM length and gender and EOM was analysed. Any anatomical variation in the EOMs dissected would be noted. Results: Mean (±SD) lengths in numerical order were: levator palpebrae superioris, 42.8±4.6mm, superior oblique, 39.2±4.5mm, medial rectus, 38.5±3.1mm, lateral rectus, 38.4±2.4mm, superior rectus, 38.2±4.1mm, inferior rectus, 37.2±2.4mm and inferior oblique, 22.5±4.4mm. Mean (±SD) cross-sectional diameters in numerical order were: medial rectus, 7.9±1.2mm, lateral rectus, 6.7±1.4mm, superior rectus,6.5±1.3mm, inferior oblique, 6.5±0.9mm, inferior rectus, 6.2±0.9mm, levator palpebrae superioris, 6.0±1.1mm and superior oblique 4.3±1.1mm. There was no significant difference between left and right sides for length and cross-sectional diameter. There was also no association between age and length and age and cross-sectional diameter. There was no association between gender and length and gender and cross-sectional diameter. Conclusion: This study presents normative measurements for EOM length and cross-sectional diameter. One anatomical variation was found: a thin muscle belly passing medially and originating from the same point as the LPS. This is estimated to occur in 8-15% of cases. Although no anatomical variations in the rectus muscles were observed this is likely due to their much lower frequency.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Specific force of the rat extraocular muscles, levator and superior rectus, measured in situ.

Extraocular muscles are characterized by their faster rates of contraction and their higher resistance to fatigue relative to limb skeletal muscles. Another often reported characteristic of extraocular muscles is that they generate lower specific forces (sP(o), force per muscle cross-sectional area, kN/m(2)) than limb skeletal muscles. To investigate this perplexing issue, the isometric contrac...

متن کامل

Histopathologic Changes of Extraocular Mus-cle Fibers after Injection of Botulinum Toxin

Background: Use of botulinum toxin is becoming a popular way in treatment of some forms of strabismus.To evaluate the morphological changes in the orbital surface layer muscles of the rabbit eye following a single injection of botulinum toxin. Methods: 10 white Dutch rabbits weighing 2–3 kg received either 10 units (group 1; n=5) or 20 units (group 2; n=5) of botulinum toxin into the superior r...

متن کامل

Histology and Physiology of the Extraocular Muscles

As described in Chapter 4, the extraocular muscles perform two functions: optostatic and optokinetic. The optostatic function requires that the muscles maintain a state of postural tonicity; the optokinetic function requires that quick, tetanic contractions be performed. These two contradictory functions are served by two different sets of muscles in the skeletal muscle system. Eye muscles, how...

متن کامل

Normal measurements of extraocular muscle using computed tomography.

OBJECTIVE Establish criteria for the diameters of normal extraocular muscles using computerized tomography in a Thai population. MATERIAL AND METHOD Diameters of extraocular muscles (medial, lateral, superior complex, and inferior rectus) were calculated for 200 patients on coronal direction of screening paranasal sinuses. The effects of age and sex were also analyzed. RESULT Normal ranges ...

متن کامل

Using morphologic parameters of extraocular muscles for diagnosis and follow-up of Graves' ophthalmopathy: diameters, areas, or volumes?

OBJECTIVE The objective of this study was to find the most appropriate, accurate, and convenient muscle parameter that can be used as a substitute for volume in monitoring the effectiveness of therapy of patients with Graves' ophthalmopathy. SUBJECTS AND METHODS The four rectus muscles in 110 orbits (35 patients and 20 control subjects) were evaluated with MR imaging. The diameter at the larg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015