Needle Insertion in CT Scanner with Image Overlay - Cadaver Studies

نویسندگان

  • Gabor Fichtinger
  • Anton Deguet
  • Ken Masamune
  • Emese Balogh
  • Gregory S. Fischer
  • Hervé Mathieu
  • Russell H. Taylor
  • Laura M. Fayad
  • S. James Zinreich
چکیده

An image overlay system is presented to assist needle placement in conventional CT scanners. The device consists of a flat LCD display and a half mirror and is mounted on the gantry. Looking at the patient through the mirror, the CT image appears to be floating inside the patient with correct size and position, thereby providing the physician with two-dimensional “X-ray vision” to guide needle placement procedures. The physician inserts the needle following the optimal path identified in the CT image that is rendered on the LCD and thereby reflected in the mirror. The system promises to increase needle placement accuracy and also to reduce X-ray dose, patient discomfort, and procedure time by eliminating faulty insertion attempts. We report cadaver experiments in several clinical applications with a clinically applicable device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Needle insertion in CT Scanner with Image Overlay - Phantom and Cadaver Studies -

We present an image overlay system that assists in surgical needle insertions inside conventional CT scanners. The device is mounted on the gantry of the CT scanner and consists of a flat LCD display and a semi-transparent mirror. In the preoperative calibration process the overlay system and the imaging plane of the scanner are registered. As a result, looking at the patient through the mirror...

متن کامل

Image overlay for CT-guided needle insertions.

OBJECTIVE We present a 2D image overlay device to assist needle placement on computed tomography (CT) scanners. MATERIALS AND METHODS The system consists of a flat display and a semitransparent mirror mounted on the gantry. When the physician looks at the patient through the mirror, the CT image appears to be floating inside the body with correct size and position as if the physician had 2D '...

متن کامل

MRI image overlay: application to arthrography needle insertion.

Magnetic Resonance Imaging (MRI) offers great potential for planning, guiding, monitoring and controlling interventions. MR arthrography (MRAr) is the imaging gold standard for assessing small ligament and fibrocartilage injury in joints. In contemporary practice, MRAr consists of two consecutive sessions: (1) an interventional session where a needle is driven to the joint space and MR contrast...

متن کامل

MRI image overlay: applications to arthrography needle insertion.

Magnetic Resonance Imaging (MRI) has unmatched potential for planning, guiding, monitoring and controlling interventions. MR arthrography (MRA) is the imaging gold standard to assess small ligament and fibrocartilage injury in joints. In contemporary practice, MRA consists of two consecutive sessions: 1) an interventional session where a needle is driven to the joint space and gadolinium contra...

متن کامل

Validation System of MR Image Overlay and Other Needle Insertion Techniques

In order to develop accurate and effective augmented reality (AR) systems used in MR and CT guided needle placement procedures, a comparative validation environment is necessary. Clinical equipment is prohibitively expensive and often inadequate for precise measurement. Therefore, we have developed a laboratory validation system for measuring operator performance using different assistance tech...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004