Ambulatory esophageal pH monitoring: new directions.
نویسندگان
چکیده
pH testing remains a commonly used evaluative tool in clinical practice. However, the original tool that included a nasally placed pH catheter was plagued with a variety of shortcomings, primarily the effect of the procedure on patients' lifestyle and thus on reflux-provoking activities. The miniaturization of evaluative techniques in gastroenterology was the impetus for the development of the wireless pH capsule and the SmartPill. These modalities improve patients' tolerability of the required test and provide a unique opportunity for expansion of indications and data collection. The introduction of the multichannel intraluminal impedance with a pH sensor allowed the detection of gastroesophageal reflux that is non-acidic. However, the value of the technique beyond the realm of academic gastroenterology remains to be elucidated. Recently, there was a renewal of interest in Bilitec 2000. The technique, which has never found a clear clinical role, has been recommended as an important tool in evaluating patients who failed proton pump inhibitor therapy. However, data to support its clinical value in this situation have remained scant.
منابع مشابه
How to Interpret Ambulatory 24 hr Esophageal pH Monitoring
Newer developing techniques for esophageal functional testing such as wireless pH capsule monitoring and esophageal impedance testing are currently available. However, ambulatory 24 hr esophageal pH monitoring is still widely used and provides quantitative data on esophageal acid exposure and the ability to correlate symptoms with acid exposure events. To properly analyze the result of pH monit...
متن کاملIneffective esophageal motility and gastroesophageal reflux disease: a close relationship?
BACKGROUND/AIMS An association between ineffective esophageal motility and gastroesophageal reflux disease is already known, but there are also some conflicting data. We evaluated the association between ineffective esophageal motility and gastroesophageal reflux disease in patients who underwent ambulatory pH monitoring for the evaluation of reflux symptoms at Gazi University, Gastroenterology...
متن کاملNormal Ambulatory 24-Hour Esophageal pH Values in Koreans -A Multicenter Study-
Ambulatory 24-hr esophageal pH monitoring is considered the gold standard for diagnosing gastroesophageal reflux disease. The aim of this study was to establish normal values for gastroesophageal acid exposure in healthy Koreans. Fifty healthy volunteers (24 males and 26 females; mean age, 45 yr) without reflux symptoms and without reflux esophagitis or hiatal hernia on upper endoscopy underwen...
متن کاملDiagnostic difficulties during combined multichannel intraluminal impedance and pH monitoring in patients with esophagitis or Barrett's esophagus.
Gastroesophageal reflux disease (GERD) is one of the most common esophageal diseases in developed countries. It is widely believed that GERD symptoms are caused by acid refluxate within the esophagus, so ambulatory 24 hour pH-monitoring became the gold standard in detecting gastroesophageal reflux. Traditional ambulatory pH monitoring is unable to detect a gastroesophageal reflux with pH >4. Th...
متن کاملResearch on Gastroesophageal Reflux Disease Based on Dynamic Features of Ambulatory 24-Hour Esophageal pH Monitoring
Ambulatory 24-hour esophageal pH monitoring has been considered as the gold standard for diagnosing gastroesophageal reflux disease (GERD), and in clinical application, static parameters are widely used, such as DeMeester score. However, a shortcoming of these static variables is their relatively high false negative rate and long recording time required. They may be falsely labeled as nonreflux...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Digestive diseases
دوره 24 3-4 شماره
صفحات -
تاریخ انتشار 2006