Reduction in MRSA environmental contamination with a portable HEPA-filtration unit.

نویسندگان

  • T C Boswell
  • P C Fox
چکیده

There is renewed interest in the hospital environment as a potentially important factor for cross-infection with methicillin-resistant Staphylococcus aureus (MRSA) and other nosocomial pathogens. The aim of this study was to evaluate the effectiveness of a portable high-efficiency particulate air (HEPA)-filtration unit (IQAir Cleanroom H13, Incen AG, Goldach, Switzerland) at reducing MRSA environmental surface contamination within a clinical setting. The MRSA contamination rate on horizontal surfaces was assessed with agar settle plates in ward side-rooms of three patients who were heavy MRSA dispersers. Contamination rates were measured at different air filtration rates (60-235 m(3)/h) and compared with no air filtration using Poisson regression. Without air filtration, between 80% and 100% of settle plates were positive for MRSA, with the mean number of MRSA colony-forming units (cfu)/10-h exposure/plate ranging from 4.1 to 27.7. Air filtration at a rate of 140 m(3)/h (one patient) and 235 m(3)/h (two patients), resulted in a highly significant decrease in contamination rates compared with no air filtration (adjusted rate ratios 0.037, 0.099 and 0.248, respectively; P < 0.001 for each). A strong association was demonstrated between the rate of air filtration and the mean number of MRSA cfu/10-h exposure/plate (P for trend < 0.001). In conclusion, this portable HEPA-filtration unit can significantly reduce MRSA environmental contamination within patient isolation rooms, and this may prove to be a useful addition to existing MRSA infection control measures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A review of portable air cleaner devices: purification processes, performance standards, effectiveness in controlling indoor air pollutants

Background and objective: Indoor air pollutants are among the five most important environmental health risks. In recent years, concerns regarding indoor air in buildings have increased. In this review, studies conducted on portable air cleaners have been investigated. Materials and methods: After determining the keywords and conducting comprehensive searches in the internet databases, taking i...

متن کامل

Pilot study of directional airflow and containment of airborne particles in the size of Mycobacterium tuberculosis in an operating room.

BACKGROUND Containment of airborne microorganisms to prevent transmission in a positively pressured operating room (OR) is challenging. Occupational transmission of Mycobacterium tuberculosis (M tuberculosis) to perioperative personnel has occurred, but protection of the surgical site is of equal importance. High-efficiency particulate air (HEPA) filters can mitigate occupational exposure and i...

متن کامل

Fungal Outbreaks and Infection Prevention During Demolition: Influence of High-Efficiency Particulate Air Filtration.

TO THE EDITOR—We read with interest the article by Kanamori et al [1] who reviewed fungal outbreaks linked to construction and renovation of healthcare settings. The authors selected 49 studies that reported cases of fungal outbreaks related to hospital construction, renovation, or demolition. The authors found that construction-related fungal cases seem to be in decline as only 3 published stu...

متن کامل

The impact of portable high-efficiency particulate air filters on the incidence of invasive aspergillosis in a large acute tertiary-care hospital.

BACKGROUND Worldwide, the frequency of invasive fungal infections has been increasing, with a corresponding increase in the numbers of high-risk patients. Exposure reduction through the use of high-efficiency particulate air (HEPA) filters has been the preferred primary preventive strategy for these high-risk patients. Although the efficiency and benefits of fixed HEPA filters is well proven, t...

متن کامل

Evaluation of microbial contamination of air in two haematology departments equipped with ventilation systems with different filtration devices.

BACKGROUND Nosocomial infections (NI) are above all due to health-care workers practices, but also the contamination of the environment could lead to their rise in health-care facilities. Introduction. In the last years, the incidence of NI has increased due to a substantial rise in the number of immuno-compromised patients. These patients are often gathered in hospital areas declared at "high ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of hospital infection

دوره 63 1  شماره 

صفحات  -

تاریخ انتشار 2006