Environmental assessment of three egg production systems–Part I: Monitoring system and indoor air quality

نویسندگان

  • Y. Zhao
  • T. A. Shepherd
  • H. Li
  • H. Xin
چکیده

To comprehensively assess conventional vs. some alternative laying-hen housing systems under U.S. production conditions, a multi-institute and multi-disciplinary project, known as the Coalition for Sustainable Egg Supply (CSES) study, was carried out at a commercial egg production farm in the Midwestern United States over two single-cycle production flocks. The housing systems studied include a conventional cage house (200,000 hen capacity), an aviary house (50,000 hen capacity), and an enriched colony house (50,000 hen capacity). As an integral part of the CSES project, continual environmental monitoring over a 27-month period described in this paper quantifies indoor gaseous and particulate matter concentrations, thermal environment, and building ventilation rate of each house. Results showed that similar indoor thermal environments in all three houses were maintained through ventilation management and environmental control. Gaseous and particulate matter concentrations of the enriched colony house were comparable with those of the conventional cage house. In comparison, the aviary house had poorer indoor air quality, especially in wintertime, resulting from the presence of floor litter (higher ammonia levels) and hens' activities (higher particulate matter levels) in it. Specifically, daily mean indoor ammonia concentrations had the 95% confidence interval values of 3.8 to 4.2 (overall mean of 4.0) ppm for the conventional cage house; 6.2 to 7.2 (overall mean of 6.7) ppm for the aviary house; and 2.7 to 3.0 (overall mean of 2.8) ppm for the enriched colony house. The 95% confidence interval (overall mean) values of daily mean indoor carbon dioxide concentrations were 1997 to 2170 (2083) ppm for the conventional cage house, 2367 to 2582 (2475) ppm for the aviary house, and 2124 to 2309 (2216) ppm for the enriched colony house. Daily mean indoor methane concentrations were similar for all three houses, with 95% confidence interval values of 11.1 to 11.9 (overall mean of 11.5) ppm. The 95% confidence interval values (overall mean) of daily mean PM10 and PM2.5 concentrations, in mg/m3, were, respectively, 0.57 to 0.61 (0.59) and 0.033 to 0.037 (0.035) for the conventional cage house, 3.61 to 4.29 (3.95) and 0.374 to 0.446 (0.410) for the aviary house, and 0.42 to 0.46 (0.44) and 0.054 to 0.059 (0.056) for the enriched colony house. Investigation of mitigation practices to improve indoor air quality of the litter-floor aviary housing system is warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Environmental impacts and sustainability of egg production systems.

As part of a systemic assessment toward social sustainability of egg production, we have reviewed current knowledge about the environmental impacts of egg production systems and identified topics requiring further research. Currently, we know that 1) high-rise cage houses generally have poorer air quality and emit more ammonia than manure belt (MB) cage houses; 2) manure removal frequency in MB...

متن کامل

Indoor air quality monitoring in urban areas using Smart Sensing Technology

Recently, indoor air quality has attracted the attention of policymakers and researchers as a critical issue like that of external air pollution. Indoor air quality is more important as people spend time longer indoors than outdoors. Indoor environments are closed compared to external environments providing less opportunity for the pollutants to dilute. The emissions contain many substances tha...

متن کامل

The effects of welfare-enhancing system changes on the environmental impacts of broiler and egg production.

The environmental impacts of 2 alternative UK broiler production systems that aim to improve bird welfare (a lower stocking density indoor system and the same system combined with heat exchangers for ventilation air) were compared with the baseline standard indoor system of broiler production. Furthermore, the environmental impacts of egg production in the conventional battery cage system (bann...

متن کامل

The Monitoring of Fungal Contamination in Indoor Air of Two Hospitals in Shiraz

Introduction: Hospitals, as one of the important elements in the health system, play an important role in patient’s health. Fungi are one of the effective parameters on indoor air quality. This study aimed to compare of fungal contamination of two hospitals in Shiraz City. Materials and Methods: Sampling was conducted based on NIOSH 0800 standard (1.5 meters above the ground level with one sta...

متن کامل

An Assessment of Indoor Air Quality and Thermal Comfort in Educational Spaces (Case Study: Girls' High Schools in Arak, Iran)

As s‌tudents spend one-third of their time at school, their health, comfort, and productivity are mos‌tly influenced by thermal condition and indoor air quality of classrooms. Regarding that manual window-opening is a common way for providing fresh air in classes and s‌tudents aren't allowed to change their uniform, position or control the windows during the lesson hours, providing thermal comf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 94  شماره 

صفحات  -

تاریخ انتشار 2015