Observability-Enhanced PMU Placement Considering Conventional Measurements and Contingencies
نویسنده
چکیده
Phasor Measurement Units (PMUs) are in growing attention in recent power systems because of their paramount abilities in state estimation. PMUs are placed in existing power systems where there are already installed conventional measurements, which can be helpful if they are considered in PMU optimal placement. In this paper, a method is proposed for optimal placement of PMUs incorporating conventional measurements of zero injection buses and branch flow measurements using a permutation matrix. Furthermore, the effect of single branch outage and single PMU failure is included in the proposed method. When a branch with a flow measurement goes out, the network loses one observability path (the branch) and one conventional measurement (the flow measurement). The permutation matrix proposed here is able to model the outage of a branch equipped with a flow measurement or connected to a zero injection bus. Also, measurement redundancy, and consequently measurement reliability, is enhanced without increasing the number of PMUs; this implies a more efficient usage of PMUs than previous methods. The PMU placement problem is formulated as a mixed-integer linear programming that results in the global optimal solution. Results obtained from testing the proposed method on four well-known test systems in diverse situations confirm its efficiency.
منابع مشابه
Observability-Enhanced PMU Placement Considering Conventional Measurements and Contingencies
Phasor Measurement Units (PMUs) are in growing attention in recent power systems because of their paramount abilities in state estimation. PMUs are placed in existing power systems where there are already installed conventional measurements, which can be helpful if they are considered in PMU optimal placement. In this paper, a method is proposed for optimal placement of PMUs incorporating conve...
متن کاملOptimal PMU Placement Considering with HVDC Links and Their Voltage Stability Requirements
In wide area measurement systems, PMUs are the main component measuring real time synchronized data from different buses. Installation of PMUs at all buses is a primary way to provide full observability of the power network. However, it is not practical in real networks due to the relatively expensive cost of PMUs and other technical limitations. Optimal PMU Placement (OPP) is an optimization p...
متن کاملOptimal Phasor Measurement Unit Placement in the Observability of Power System by using Spanning Tree Algorithm
Phasor Measurement Unit’s (PMU) are power system devices which provide real time synchronized phasor measurements. Synchronization is achieved by same-time sampling of voltage and current waveforms by means of timing signals from the Global Positioning System Satellite (GPS). Synchronized phasor measurements make higher the standards of power system monitoring, control, and protection. Since PM...
متن کاملOptimal Placement of Phasor Measurement Units to Maintain CompleteObservability Considering Maximum Reliability by Non-dominated Sorting Genetic Algorithm-II (NSGA-II)
Ever-increasing energy demand has led to geographic expansion of transmission lines and their complexity. In addition, higher reliability is expected in the transmission systemsdue to their vital role in power systems. It is very difficult to realize this goal by conventional monitoring and control methods. Thus, phasor measurement units (PMUs) are used to measure system parameters. Although in...
متن کاملOptimal Placement of Phasor Measurement Units in Khorasan Network Using a Hybrid Intelligent Technique
In this paper, an efficient and comprehensive hybrid intelligent technique for the optimal placement of phasor measurement units (PMUs) is proposed to minimize the number of PMU installation subjected to full network observability. Three main purposes of PMUs output synchronous measurements are monitoring, control, and protection of power system. We have combined Binary Imperialistic Competitio...
متن کامل