Emission of airborne bacteria from a hospital incinerator.

نویسندگان

  • R J Allen
  • G R Brenniman
  • R R Logue
  • V A Strand
چکیده

Only five studies have been found in the literature which provide any indication of the effectiveness of incineration for rendering infectious hospital waste innocuous. Although there is an indication from these studies for release of bacteria in stack gas, none of the studies identified the bacteria or determined the source of bacteria. The purpose of the present study was to investigate the potential for a hospital incinerator to release human pathogenic bacteria into the ambient environment. In this study, waste spiked with Bacillus subtillis was burned in a hospital incinerator. Although bacteria were found in the incinerator stack gas, (concentrations ranged from not detectable to 1157 colonies/m3 of air) no Bacillus subtilis was recovered from the stack gas. The results suggest that the source of the stack gas bacteria was not from unburned waste or from outdoor air. Analysis of samples of air from the incinerator room (not simultaneous with the stack gas samples) indicates that the source of the stack gas bacteria was most likely the combustion air.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Effects of Deep and Surface Aeration Methods on Density and Type of Airborne Bactria and Fungi in Municipal Wastewater Treatment Plant

Background and purpose: Emission of bioaerosols from wastewater treatment plants is a potential hazard to human health. In this study aimed at investigating the effects of surface and deep aeration techniques on density and type of airborne bacteria and fungi in two municipal wastewater treatment plants. Materials and methods: This descriptive cross-sectional study was done in two wastewater t...

متن کامل

Emission of viable bacteria in the exhaust flue gases from a hospital incinerator.

The exhaust gases from an oil-fired hospital waste incinerator were examined during normal incinerator operation. The design-specified operating temperature was 800 degrees C in the primary combustion chamber and 1000 degrees C in the secondary chamber. Flue gas temperatures, measured from the sampling point at the base of the exhaust stack, varied over the range 186-305 degrees C, and bacteria...

متن کامل

Indoor Airborne Bio Aerosols in Valiasr Hospital in Zanjan, Iran

Background: Bio aerosols include airborne micro-organisms such as bacteria, fungi, viruses, etc and their products. Exposure to a bio aerosol is linked with a broad spectrum of health problems, including infectious diseases, acute toxic effects, allergies, and cancer. The aim of this study was to evaluate the quality and quantity of bio aerosols found in the air of different wards in Valiasr Ho...

متن کامل

Toxic Emissions from Hospital Incinerators

I Data from large incinerators shows the potential release of dioxins, heavy metals, and acid gases as air pollutants. Hospital incinerators can present similar problems to a much greater degree, especially ,sinc-e,most of these smaller incinerators do not have effective c'ijmbustion or emission controls and their emissions are poorly dispersed. high content of plastics in the waste. potential ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JAPCA

دوره 39 2  شماره 

صفحات  -

تاریخ انتشار 1989