[Pelvic discontinuity in revision total hip arthroplasty--case report].

نویسندگان

  • Josko Smilović
  • Damir Matoković
  • Dubravko Orlić
چکیده

Revision total hip arthroplasty with massive bone loss and pelivic discontinuity has no standardized treatment up until now. This report presents a case of a female patient with a diagnosed pelvic discontinuity 4 years after the previous hip arthroplasty. The patient is suffering from rheumatoid arthritis, and was admitted to hospital treatment for hip pain, leg shortening, limitated range of motion and the inability to walk. Pelvic discontinuity was identified in preoperative radiographs of the pelvic and hip region, and intraoperatively it was determined that it was a type IV b discontinuity according classifications for acetabular defects defined by AAOS, and subclassification of type IV according Berry et al., that is discontinuity associated with cavitary and segmental acetatabular bone loss. In the goal of achieveing a stable construction, as a vital prerequisite for achieving bone consolidation, an osteosynthesis of the posterior column was done with a reconstructive plate by A.O. method, and afterwards the defect was filed with bone transplants from the bone transplant bank. An adequate revision cementless cup was installed, and screws were used to achieve a good fixation of the bigger modeled bone transplants and the fixation of the cup for the remainder of the pelvis. By that method a good inicial stability of construction was achieved. In the goal of achieving bone ingrowth and avoidance of mechanical failure it was advised an avoidance of weight bearing in the period of 3-6 months after the operation. With the method of reconstruction we applied after 2 years of follow-up the cinical result was satisfactory, and radiologicaly there are no signs of construction loosening so it can be claimed that the discontinuity was cured.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Twenty-year survival of a cementless revision hip arthroplasty using a press-fit bulk acetabular allograft for pelvic discontinuity: a case report.

Acetabular revision in a total hip arthroplasty (THA) with pelvic discontinuity is uncommon and challenging. Optimal management remains controversial, particularly with graft and implant selection. Interpretation of outcomes is confounded by the heterogeneity of patterns of bone loss and the lack of long-term results in great numbers for any given choice of treatment. We report a revision THA u...

متن کامل

Reconstruction of acetabulum in revision total hip arthroplasty for pelvic discontinuity: report of a difficult case requiring four revision arthroplasty

BACKGROUND Massive bone defects of the acetabulum with pelvic discontinuity are one of the major problems in revision total hip arthroplasty. Several techniques have been described for repair of acetabular defect; however, reconstruction of acetabulum with massive bone defect is still a major problem. We describe a patient who required four revision total hip arthroplasty during a 24-year perio...

متن کامل

[Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis].

BACKGROUND The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. CASE REPORT The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had diffic...

متن کامل

Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature

Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...

متن کامل

Hip Arthroplasty and its Revision in a Child: Case Report and Literature Review

Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...

متن کامل

Delayed diagnosis of catastrophic ceramic liner failure with resultant pelvic discontinuity and massive metallosis

With newer-generation ceramic components used in total hip arthroplasty, component fracture is a rare complication. However rare, when ceramic component fracture does occur, prompt identification and revision is necessary as delay can lead to dramatic failure with resultant metallosis as the extremely hard ceramic debris abrades remaining components. We present a case of a 70-year-old woman wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lijecnicki vjesnik

دوره 135 1-2  شماره 

صفحات  -

تاریخ انتشار 2013