Accuracy of Zernike polynomials in characterizing optical aberrations and the corneal surface of the eye.

نویسنده

  • Luis Alberto Carvalho
چکیده

PURPOSE Zernike polynomials have been successfully used for approximately 70 years in many different fields of optics. Nevertheless, there are some recent discussions regarding the precision and accuracy of these polynomials when applied to surfaces such as the human cornea. The main objective of this work was to investigate the absolute accuracy of Zernike polynomials of different orders when fitting several types of theoretical corneal and wave-front surface data. METHODS A set of synthetic surfaces resembling several common corneal anomalies was sampled by using cylindrical coordinates to simulate the height output files of commercial videokeratography systems. The same surfaces were used to compute the optical path difference (wave-front [WF] error), by using a simple ray-tracing procedure. Corneal surface and WF error was fit by using a least-squares algorithm and Zernike polynomials of different orders, varying from 1 to 36 OSA-VSIA convention terms. RESULTS The root mean square error (RMSE) ranged-from the most symmetric corneal surface (spherical shape) through the most complex shape (after radial keratotomy [RK]) for both the optical path difference and the surface elevation for 1 through 36 Zernike terms-from 421.4 to 0.8 microm and 421.4 to 8.2 microm, respectively. The mean RMSE for the maximum Zernike terms for both surfaces was 4.5 microm. CONCLUSIONS These results suggest that, for surfaces such as that present after RK, in keratoconus, or after keratoplasty, even more than 36 terms may be necessary to obtain minimum accuracy requirements. The author suggests that the number of Zernike polynomials should not be a global fixed conventional or generally accepted value but rather a number based on specific surface properties and desired accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

اصلاح توام نقص ابیراهی لنز دوربین و خطای خروج از مرکز تصویر با بهره‌گیری از مدل اصلاح شده زرنیک

Reduction of the quality of the image formed by an optical system is a function of different parameters such as lens aberrations, CCD digitization errors, and the errors of system assembling. Assembling errors usually consist of two types: 1) the prism error, which is the error of non-orthogonality of the optical axis and the image plane 2) the de-centering error, which is error of not passing ...

متن کامل

Identification of Corneal Aberrations by using Computer Techniques

The objective was to study the relative contributions of optical aberrations of the cornea and determine the irregularities across its surface area. Corneal topographic imaging data is used and corneal aberrations are computed by using corneal height maps. Mathematical modeling of cornea surface is developed by using Zernike polynomials and they are compared with the patient corneas. Simulation...

متن کامل

Dynamic changes in the tear film in dry eyes.

PURPOSE To examine the dynamics of the tear film in patients with dry eye by measuring the wavefront aberrations of the anterior surface of the film. METHODS Anterior surface aberrations for a 7-mm pupil were determined in 13 patients with dry eye at 1-second time intervals, for 15 seconds after a blink. The aberrations were calculated from the elevations provided by corneal topography. All d...

متن کامل

Comparison of Zernike and Fourier wavefront reconstruction algorithms in representing the corneal aberration of normal and abnormal eyes

Purpose: The goal of this study was to investigate with what accuracy the Zernike and Fourier reconstruction algorithms can describe the corneal aberration in normal and abnormal eyes. Methods: Corneal topography (Orbscan IIz) was collected on 87 normal, 27 keratoconus, 9 penetrating keratoplasty (PKP), and 20 post-LASIK symptomatic eyes. Raw topography images were converted into elevation maps...

متن کامل

Evaluation of Aberrations in the Optical System of the Human Eye Based on the Spatial Spectrum of a Diagnostic Image

This study deals with the analysis of wavefront aberrations that occur in the image owing to curvature variations in the human eye cornea. The analysis is based on the Liou-Brennan human eye model. The surface curvature and wavefront aberrations are described using Zernike polynomials. Our approach involves evaluating parameters of the distorting system's transfer function and measuring the exp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 46 6  شماره 

صفحات  -

تاریخ انتشار 2005