Potential Stable Low-Permeation Rate Standard Based on Micro-machined Silicon

نویسندگان

  • Adrian Verwolf
  • Chris Poling
  • Nick Barbosa
  • Grady White
  • Nikki Rentz
چکیده

Silicon wafers with micro-machined holes were evaluated for use as low-permeation-rate standard artifacts. Accuracy, stability, and reliability were assessed. Two independent experimental techniques for evaluating permeation were used: chilled mirror hygrometer and mass loss. The wafers exhibited a well-defined linear relationship between hole area and resultant water partial pressure for both techniques, although the mass loss curve exhibited a constant vertical offset from the hygrometer curve, attributed to water loss through the O-ring seal. In contrast to polymer permeation standards, Si wafers provided long-term reproducible permeation rates. However, they were also highly fragile, with most of them cracking during the course of the investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Micro Fluidic Channel Machining on Fused Silica Glass Using Powder Blasting

In this study, micro fluid channels are machined on fused silica glass via powder blasting, a mechanical etching process, and the machining characteristics of the channels are experimentally evaluated. In the process, material removal is performed by the collision of micro abrasives injected by highly compressed air on to the target surface. This approach can be characterized as an integration ...

متن کامل

A mechanical micro molecular mass sensor

One of the bio-sensing mechanisms is mechanical. Rather than measuring shift in resonance frequency, we adopt to measure the change in spring constant due to adsorption, as one of the fundamental sensing mechanism. This study explains  determination of spring constant of a surface functionalized micro machined micro cantilever, which resonates in a trapezoidal cavity-on Silicon wafer, with the ...

متن کامل

A mechanical micro molecular mass sensor

One of the bio-sensing mechanisms is mechanical. Rather than measuring shift in resonance frequency, we adopt to measure the change in spring constant due to adsorption, as one of the fundamental sensing mechanism. This study explains  determination of spring constant of a surface functionalized micro machined micro cantilever, which resonates in a trapezoidal cavity-on Silicon wafer, with the ...

متن کامل

A Short Review on Fabrication Methods of Micro-Cantilever for Ionic Electroactive Polymer Sensors/Actuators

   Micro-electroactive polymers have wide applications from industry to healthcare. Artificial muscles, microvalves, microswitches, haptic sensing, blood pressure and pulse monitoring are some potential applications for micro-electroactive polymers. The most advantage of micro-electroactive polymers as sensors and actuators is bio-compatibility and low power threshold for large deformations...

متن کامل

Low helium permeation cells for atomic microsystems technology.

Laser spectroscopy of atoms confined in vapor cells can be strongly affected by the presence of background gases. A significant source of vacuum contamination is the permeation of gases such as helium (He) through the walls of the cell. Aluminosilicate glass (ASG) is a material with a helium permeation rate that is many orders of magnitude lower than borosilicate glass, which is commonly used f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 120  شماره 

صفحات  -

تاریخ انتشار 2015