Dose gradient impact on equivalent dose at 2 Gy for high dose rate interstitial brachytherapy
نویسندگان
چکیده
PURPOSE To evaluate a new calculation model estimating the equivalent dose at 2 Gy (EQD2) taking into account dose gradient in high dose rate interstitial brachytherapy (HDRIB). MATERIAL AND METHODS Forty dose-volume histograms (DVHs) of breast (20 pts) and prostate (20 pts) cancer dose distributions were reviewed. Physical prescribed doses (PPD) were 34 Gy (10f/5d) and 18 Gy (6f/2d) for breast (partial irradiation protocol) and prostate (boost after external irradiation) treatment, respectively. For each DVH, clinical target volume (CTV), V100, V150, V200, D90 and D100 were determined. Based on DVH segmentation, elementary doses (d) delivered to elementary volumes were determined, then multiplied by C (% of CTV receiving d). According to the linear quadratic model, EQD2 was calculated for different α/β ratios. RESULTS For breast implant, median EQD2 (α/β = 4) was 42 Gy and 76 Gy (66-85) without and with dose gradient consideration, respectively. For prostate implant, median EQD2 (α/β = 1.5) was 39 Gy and 98 Gy (90-103) whether dose gradient was not or was taken into account, respectively. CONCLUSIONS This study pointed out that for brachytherapy, EQD2 calculation must take into account the dose gradient. Because this model is a mathematical one, it has to be cautiously applied. Nevertheless, it appears as a useful tool for EQD2 comparison between the same PPD delivered through EBRT or brachytherapy regarding trial result interpretation.
منابع مشابه
Evaluation of neuropathic pain occurring after high-dose-rate interstitial brachytherapy of oral tongue
PURPOSE To recognize neuropathic pain as a complication of high-dose-rate (HDR) interstitial brachytherapy of oral tongue and to evaluate the possible causes of neuropathy. MATERIAL AND METHODS Twenty one patients who underwent interstitial brachytherapy for early cancer of oral tongue were evaluated. The patients either underwent primary brachytherapy (42-48 Gy at 3-4 Gy/fraction) or a boost...
متن کاملApplicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film
Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...
متن کاملCalculation of absorbed dose rate in the lungs, ribs and skin by the mammosite applicator in breast cancer brachytherapy with MCNP
Introduction: Breast cancer is the most common cancer among women. Brachytherapy is one of the ways to treat breast cancer. In brachytherapy treatments, high-dose sources are used in interstitial placement. Here, Iridium-192 is used. This source emits gamma rays with energies ranging from 136 kV to 1060 kV electron volts. The activity of the used spring is 10 Ci. The simulated ...
متن کاملEvaluation of dose distribution and dose gradient in brachytherapy cylindrical applicators using a dedicated Phantom for Iridium-192 and Cobalt-60 HDR sources
Introduction: A study was performed to evaluate radiation dose distribution and dose gradient around cylindrical applicators for high-dose-rate (HDR) brachytherapy systems with 192Ir, 60Co brachytherapy source applied for rectal and vaginal cancers treatments. Materials and Methods: Two additional computed tomography (CT) based plans were generated using a ...
متن کاملHigh-dose-rate interstitial brachytherapy in head and neck cancer: do we need a look back into a forgotten art – a single institute experience
PURPOSE To evaluate the treatment outcomes with high-dose-rate (HDR) interstitial brachytherapy (HDR-BRT) in head and neck cancers (HNC). MATERIAL AND METHODS Fifty-eight patients with HNC as per American Joint Committee on Cancer (AJCC) TNM staging criteria were analyzed retrospectively between 2008 and 2015. Forty-two patients received external beam radiotherapy (EBRT) with HDR-BRT and 16 p...
متن کامل