Axial eye length measurements pre-and post-laser-assisted in situ keratomileusis using the IOL Master: a pilot study

نویسندگان

  • Spyridon E Chalkiadakis
  • Georgios A Amariotakis
  • Efstratios A Parikakis
  • Vasileios G Peponis
چکیده

PURPOSE A preliminary study in order to test the accuracy of the IOL Master in detecting axial eye length changes after laser-assisted in situ keratomileusis and to correlate the findings with the theoretical ablation depth. METHODS Pre-and postoperative axial eye length measurements were performed in 10 consecutive eyes that underwent laser-assisted in situ keratomileusis with the Alcon Ladar Vision excimer laser to treat myopic refractive errors ranging from -2.50 to -8.00 diopters of spherical equivalent (mean: -5.23 ± 1.30 D). RESULTS The preoperative axial eye length measurements ranged from 24.53 mm to 27.78 mm (mean: 25.80 ± 1.01 mm) and from 24.57 mm to 27.57 mm (mean: 25.68 ± 0.93 mm) 1 month after the operation. Preoperative and 1-month postoperative data showed a statistically significant difference (P < 0.05). CONCLUSIONS The IOL Master showed a decrease in the axial eye length measurements that was bigger than the theoretical ablation depth and did not correlate well with it. Such data need to be confirmed by a larger cohort of patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical biometry before and after excimer laser epithelial keratomileusis (LASEK) for myopia.

PURPOSE In order to select the correct intraocular lens (IOL) for implantation, it is important to measure the eye length (biometry). The IOL Master from Zeiss-Humphry is frequently used for such measurements. Because this instrument employs an optical method, any irregularities on the corneal surface or any disturbances in corneal transparency could lead to mistakes in the measurements. The ai...

متن کامل

Prediction accuracy of intraocular lens power calculation methods after laser refractive surgery

BACKGROUND This study aimed to evaluate the prediction accuracy of postoperative refractions using partial coherence interferometry (IOL-Master) and applanation ultrasound (AL-3000) assisted with corneal topography (TMS-4) in eyes that had undergone myopic laser-assisted in situ keratomileusis (LASIK). METHODS Haigis-L formula, Koch-Maloney method using Haigis formula, Shammas clinically deri...

متن کامل

Customized eye models for determining optimized intraocular lenses power

We have developed a new optical procedure to determine the optimum power of intraocular lenses (IOLs) for cataract surgery. The procedure is based on personalized eye models, where biometric data of anterior corneal shape and eye axial length are used. A polychromatic exact ray-tracing through the surfaces defining the eye model is performed for each possible IOL power and the area under the ra...

متن کامل

No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis.

PURPOSE To prospectively evaluate the no-history method for intraocular lens (IOL) power calculation in 15 cataractous eyes that had previous myopic laser in situ keratomileusis (LASIK) and for which the pre-LASIK K-readings were not available. SETTING Private practice, Lynwood, California, USA. METHODS The predicted IOL power was calculated in each case. Also calculated were the mean arith...

متن کامل

Comparison of the biometric measurements calculated with Zeiss IOL-Master and WaveLight OB-820

BACKGROUND The primary objective of this study was to investigate the level of agreement between IOL-Master and OB-820 ocular biometers. MATERIALS AND METHODS In this prospective randomized case series, we measured the anterior chamber depth (ACD), the axial length (AL), the corneal radii (R1, R2), the ratio of mean corneal radius and spherical equivalent and the corneal astigmatism (cylinder...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2010