Dosimetric effects of immobilization devices on SABR for lung cancer using VMAT technique

نویسندگان

  • Jong In Park
  • Sung‐Joon Ye
  • Hak Jae Kim
  • Jong Min Park
چکیده

The purpose of this study was to investigate the dosimetric effects of immobilization devices on the dose distributions of stereotactic ablative radiotherapy (SABR) for lung cancer using volumetric-modulated arc therapy (VMAT) technique. A total of 30 patients who underwent SABR for lung cancer were selected retrospectively. Every patient was immobilized using Body Pro-Lok with a vacuum bag customized for each patient body shape. Structure sets were generated to include the patient body inside the body structure with and without the immobilization device. Dose distributions, with and without the immobilization device, were calculated using identical VMAT plans for each patient. Correlations between the change in dose-volumetric parameters and the MU fraction of photon beams penetrating through the immobilization device were analyzed with Pearson correlation coefficients (r). The maximum change in D95%, D100%, and the minimum, maximum and mean dose to the planning target volume (PTV) due to the immobilization device were 5%, 7%, 4%, 5%, and 5%, respectively. The maximum changes in the maximum dose to the spinal cord, esophagus, heart, and trachea were 1.3 Gy, 0.9 Gy, 1 Gy, and 1.7 Gy, respectively. Strong correlations were observed between the changes in PTV D95%, the minimum, the maximum, and the mean dose to the PTV, the maximum dose to the esophagus and heart, and the MU fractions, showing values of r higher than 0.7. The decrease in dose to the target volume was considerable for lung SABR using VMAT technique, especially when MU fraction was large.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comprehensive dosimetric planning comparison for early‐stage, non‐small cell lung cancer with SABR: fixed‐beam IMRT versus VMAT versus TomoTherapy

Volumetric-modulated arc therapy (VMAT) is emerging as a leading technology in treating early-stage, non-small cell lung cancer (NSCLC) with stereotactic ablative radiotherapy (SABR). However, two other modalities capable of deliver-ing intensity-modulated radiation therapy (IMRT) include fixed-beam and helical TomoTherapy (HT). This study aims to provide an extensive dosimetric compari-son amo...

متن کامل

Optimization of the dosimetric leaf gap for use in planning VMAT treatments of spine SABR cases

The dosimetric leaf gap (DLG) is a beam configuration parameter used in the Varian Eclipse treatment planning system, to model the effects of rounded MLC leaf ends. Measuring the DLG using the conventional sliding-slit technique has been shown to be produce questionable results for some volumetric modulated arc therapy (VMAT) treatments. This study therefore investigated the use of radiochromic...

متن کامل

A comparison of three different VMAT techniques for the delivery of lung stereotactic ablative radiation therapy.

INTRODUCTION The purpose of this study was to investigate coplanar and non-coplanar volumetric modulated arc therapy (VMAT) delivery techniques for stereotactic ablative radiation therapy (SABR) to the lung. METHODS For ten patients who had already completed a course of radiation therapy for early stage lung cancer, three new SABR treatment plans were created using (1) a coplanar full arc (FA...

متن کامل

Bilateral Breast Irradiation Using Hybrid Volumetric Modulated Arc Therapy (h- VMAT) Technique: A Planning Case Report

The purpose of this planning case report is to share the perceived dosimetric benefits of innovative hybrid volumetric modulated arc therapy (h-VMAT) for bilateral breast cancer radiotherapy in two patients with synchronous bilateral breast cancer. Two patients with early bilateral breast cancer after breast conservation surgery and adjuvant chemotherapy were planned for bilateral breast radiot...

متن کامل

Bilateral Breast Irradiation Using Hybrid Volumetric Modulated Arc Therapy (h-VMAT) Technique: A Planning Case Report

The purpose of this planning case report is to share the perceived dosimetric benefits of innovative hybrid volumetric modulated arc therapy (h-VMAT) for bilateral breast cancer radiotherapy in two patients with synchronous bilateral breast cancer. Two patients with early bilateral breast cancer after breast conservation surgery and adjuvant chemotherapy were planned for bilateral breast radiot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015