Twenty-year experience with the St. Jude medical Biocor bioprosthesis in the aortic position.

نویسندگان

  • Walter B Eichinger
  • Ina M Hettich
  • Daniel J Ruzicka
  • Klaus Holper
  • Carolin Schricker
  • Sabine Bleiziffer
  • Ruediger Lange
چکیده

BACKGROUND The purpose of this study was to evaluate the long-term performance of the St. Jude Medical Biocor stented porcine prosthesis in the aortic position. METHODS From January 1985 to December 1996, 455 patients admitted for aortic valve replacement were consecutively enrolled in this study. The mean age was 72.5 +/- 9 years, 18 patients (3.5%) had had previous cardiac surgery, and coronary artery bypass grafting was performed in 171 patients (37.6%). Follow-up was complete in 99.6%; up to 21 years were covered. Actuarial event-free rates are given as mean +/- standard error and adverse events were classified according to the guidelines for reporting morbidity and mortality after cardiac valvular operations. RESULTS Cumulative follow-up time was 3,321 patient-years with a mean follow-up of 8.2 years. The actuarial survival rate after 20 years was 9.4% +/- 2.8%. The actuarial rates for freedom from structural valve deterioration were 93.1% +/- 1.7% at 10 years, 88.4% +/- 3.5% at 15 years, and 70.3% +/- 10.9% at 20 years. The actuarial rates for freedom from reoperation due to structural valve deterioration were 91.9% +/- 1.6% at 10 years, 90.6% +/- 2.1% at 15 years, and 86.5% +/- 4.5% at 20 years. CONCLUSIONS This study presents one of the largest series of St. Jude Medical Biocor aortic valves in the world. Results indicate an age-dependent risk of structural valve degeneration beginning as soon as 7 years postoperatively for patients below the age of 65 years, but show a low overall incidence of valve-related complications and excellent durability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.

Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...

متن کامل

The St Jude Medical Trifecta aortic pericardial valve: results from a global, multicenter, prospective clinical study.

BACKGROUND The St Jude Medical Inc (St Paul, Minn) Trifecta valve is a novel aortic biological prosthesis that incorporates several design features, including a true supra-annular sewing cuff, a stent design that maximizes valve hemodynamics while minimizing leaflet stresses, and an ethanol-based anticalcification technology. This study establishes the safety and early clinical and hemodynamic ...

متن کامل

Midterm Follow-Up of Haemodynamic Performance of the St. Jude Medical Trifecta Aortic Bioprosthesis in Young Patients Under 65

Method Thirty consecutive patients undergoing aortic valve replacement using the St. Jude Medical Trifecta valve at a single UK centre over a 48-month period were included in this study. Patients undergoing concomitant cardiac procedures were included. All implanted valves were 21, 23, 25 and 27 mm in size. Assessment of haemodynamic function was carried out using transthoracic echocardiography...

متن کامل

Long-term Doppler echocardiographic results of aortic or mitral valve replacement with Biocor porcine bioprosthesis.

OBJECTIVES Our objectives were to evaluate the long-term bioprosthetic and cardiac functional outcome after insertion (over a 10-year period) of a new-generation porcine zero pressure-fixed Biocor bioprosthesis, as well as to determine the echocardiographic accuracy for selection of patients requiring reoperation. The long-term systematic Doppler echocardiographic assessment after valve replace...

متن کامل

Left Ventricular Mass Regression following Implantation of St. Jude Medical Trifecta Aortic Bioprosthesis

Method One hundred and seventy two consecutive patients undergoing aortic valve replacement using the St. Jude Medical Trifecta valve at a single UK centre over a 48-month period were included in this study. Patients undergoing concomitant cardiac procedures were included. All implanted valves were 19, 21, 23, 25, 27 & 29 mm in size. Patients underwent both pre-operative and post-operative tran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of thoracic surgery

دوره 86 4  شماره 

صفحات  -

تاریخ انتشار 2008