Vibration and staccato flow pattern in ventricular assist devices.

نویسندگان

  • M Dolores García-Cosío Carmena
  • Santiago Serrano-Fiz
  • Manuel Gómez Bueno
چکیده

A patient awaiting a heart transplant may need a ventricular assist device (VAD) to stabilize the clinical situation as needed, and may even be discharged. These VADs have complicated mechanics and dysfunctions can occur, sometimes related to an obstruction in the entrance cannula (EC). We present the case of a 28-year-old man with dilated-phase hypertrophic cardiomyopathy who received a Berlin Heart Excor VAD. On the tenth day after the operation, following an intense negative balance, the EC started to vibrate and there were signs that the artificial ventricle was not filling up correctly. The echocardiogram showed that the left ventricular cavity was smaller than in other studies. The color Doppler study showed a PISA effect (Fig. 1A) in the EC of the left ventricular apex (Fig. 2). The Doppler continued showing high-flow velocity in the EC with intermittent unsteady flow, coinciding with the vibration (Fig. 1B), which were indicative of an obstruction. The vibration reduced once the patient was properly hydrated, and no clinical repercussions occurred. After 111 days on VAD support, 90 of those days at home, the patient received the heart transplant. The extracted heart showed that the EC opening was very close to a prominent papillary muscle (Fig. 3). The implant was close to the deformed papillary muscle and the ventricular diameter reduced over time, which could have contributed to the obstruction. This last point explains that the alteration was manifested days after the VAD was implanted, and improved when the patient was properly hydrated. PM A B 6 m/s

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Left ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates.

OBJECTIVE Fixed pulmonary hypertension is a contraindication for cardiac transplantation because of the increased risk of donor heart failure. We sought to determine whether left ventricular assist devices improve fixed pulmonary hypertension in cardiac transplant candidates to enable safe cardiac transplantation. METHODS Thirty-five consecutive cardiac transplant candidates (age 56 +/- 6 yea...

متن کامل

Looking Inside the Third Generation Left Ventricular Assist Device Using Color Doppler Transesophageal Echocardiography

HeartWare is a third-generation continuous flow left ventricular assist device (LVAD) and generates centrifugal pattern of blood flow. In the perioperative setting, interrogating the HeartWare devices is very difficult due to the interference of the Doppler by the impeller frequency and generation of the waterfall artifact. We present a case where using color Doppler a view "inside" the impelle...

متن کامل

Acquired von Willebrand syndrome after exchange of the HeartMate XVE to the HeartMate II ventricular assist device.

Instead of pulsatile ventricular assist devices an increasing number of nonpulsatile ventricular assist devices are introduced to clinical practice. The different flow characteristics of this new technique lead to alteration in shear stress on blood components, which may affect the coagulation system. Repeated von Willebrand factor analyses were performed in a patient who first was implanted wi...

متن کامل

The National Heart, Lung, and Blood Institute Pediatric Circulatory Support Program.

Options for the circulatory support of pediatric patients under the age of 5 years are currently limited to short-term extracorporeal devices, the use of which is often complicated by infection, bleeding, and thromboembolism. Recognizing this void, the National Heart, Lung, and Blood Institute solicited proposals for the development of novel circulatory support systems for infants and children ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 66 5  شماره 

صفحات  -

تاریخ انتشار 2013