Right Ventricular Assist with Conventional Cardiopulmonary Bypass Equipment

نویسندگان

  • Michael Corrigan
  • Paul J. DiGregorio
  • Jose Soto
  • Gary S. Freeman
  • Alan Markowitz
چکیده

___________ _ A technique of supporting a patient with perioperative right ventricular failure has been developed and used clinically. The method is simple, inexpensive, effective, and involves only conventional cardiopulmonary bypass equipment. Introduction ____________ _ Right ventricular (RV) failure can account for significant patient morbidity during cardiac surgery, especially when the RV blood supply is compromised. Some of this may be reversed with prolonged support, 1.2 although implantable devices are quite cumbersome and require specialized monitoring and power sources. Using conventional equipment we have been able to rest the right ventricle for significant periods of time, with recovery of RV function. Materials and Methods _______ _ The assist circuit consists of a 500cc. collapsible reservoir," a loop of 3/8" I.D. polyvinyl chloride tubing, and a roller pump. b The 3/8" cardiotomy and venous return ports of the reservoir are connected with a "Y" connector to prevent blood from stagnating. The Direct communications to: Michael Corrigan, C.C.P., Division of Cardiothoracic Surgery, 1800 E. 105th St., Cleveland, OH 44106 a SciMed Life Systems, Inc. Minneapolis, MN 55441 b Sarns 3M Inc., Ann Arbor, MI 48013 ~ USCI, Inc., Billerica, MA 01821 Volume 18, Number 1, Spring 1986 pre-attached recirculation line supplied by the manufacturer is kept sterile by connecting it to a top port on the reservoir. While still on cardiopulmonary bypass (CPB), the assist loop can be primed and recirculated. The loop is divided into assist outlet and inlet portions. The assist outlet is connected to a 24 Fr. aortic cannulah by a "luer-lok" connector with stopcock. The cannula is inserted into the main pulmonary and de-aired through the stopcock. CPB can still be maintained with one caval cannula while a new 34 Fr. venous cannula' is inserted into the right atrium. This cannula is then connected to the assist pump inlet tubing. The patient is weaned from total CPB until heart failure becomes apparent. At this point RV assist is instituted and CPB terminated. When the patient is stable, chest tubes are placed and the chest is closed around the cannulas and tubing. Maximum output of the assist circuit is determined by gravity return via the right atrium. Patient weaning is controlled by restricting gravity drainage while reducing assist output, thus forcing the right heart to do more work. This process requires the monitoring of left atrial pressure (LAP), central venous pressure (CVP), and systemic blood pressure (BP). An elevated CVP in the presence of a low LAP and BP indicates failing right heart function, corroborated by cardiac output measurements. Anticoagulation is maintained with a heparin drip controlled by an infusion pump. Activated clotting times (ACT) should be monitored although the optimal target value for long-term support without an oxygenator is still in question. ACT should be checked every 60 The Journal of Extra-Corporeal Technology 27 minutes, and a value of 200 seconds is probably adequate. 3 Chest tube drainage, urinary output, body temperature, white blood cell count, hematocrit, platelets, electrolytes, blood gases, and fluid balance all need to be monitored. A careful record of RV assist flows is obviously crucial. Discussion _____________ _ The assist circuit employs a reservoir for additional safety. Our laboratory experience shows, in the absence of a reservoir, a positive CVP must be maintained constantly. Should the CVP approach zero, negative pressure will draw air into the assist inlet tubing through the cannula pursestring. The in-line reservoir prevents this from happening. Fluid balance, bleeding, and infection are a constant concern. Maintenance of adequate cardiac output is vital, but fluid administration should be precise and diuresis aggressive in order to reduce myocardial edema and prevent dilution of clotting factors. Due to necessary anticoagulation, blood replacement may be extensive, making careful control of the ACT absolutely essential. Since the assist tubings emerge through the skin, infection is always a risk. Sterile technique must be rigidly adhered to and prophylactic broad-spectrum 28 The Journal of Extra-Corporeal Technology antibiotics are strongly advised during the course of right heart assist. This technique has been tested experimentally and employed twice clinically for right ventricular failure. The infrequent need for long-term support at our institution makes this approach much more attractive to us than specialized, implantable, assist devices. The particular utility of this approach with conventional perfusion techniques obviates the need for more sophisticated support in those very difficult patients. Addendum Presently we are using a centrifugal pump for ventricular assist. This non-occlusive pump eliminates the need for the reservoir and reduces the extent of required anticoagulation. References _______________________ __ I. Pierce, W.S., Parr, G.V.S., Myers, J.L., Pae, W.E., Bull, A.P., and Waldhausen, J.A.: Ventricular-assist pumping in patients with cardiogenic shock after cardiac operations. N. Engl. J. Med. 305(27):1606-10, 1981. 2. Bernard, W.F., Berger, R.L., Stetz, J.P., Carr, J.G., Colo, N.A., McCormick, J.R., and Fishbein, M.C.: Temporary left ventricular bypass: factors affecting patient survival. Circulation 60 (Suppl I): I-131, 1979. 3. Rose, D.M., Colvin, S.H., Culliford, A.T., Cunningham, J.N., Adams, P.X., Glassman, E., Isom, O.W., and Spencer, F.C.: Long-term survival with partial left heart bypass following perioperative myocardial infarction and shock. J. 7horac. Cardiovasc. Surg. 83:483-492, 1982. Volume 18, Number 1, Spring 1986

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel multi-functional life support system.

UNLABELLED Concepts of cardiopulmonary support (CPS), extracorporeal membrane oxygenation (ECMO), and ventricular support (VS) have been thoroughly studied and refined. These perfusion adjuncts often require multiple devices, skill sets, and significant financial burden to purchase, maintain, deploy, and use. We describe a novel system that is rapidly deployable, user-friendly, portable, safe, ...

متن کامل

A simplified cardiopulmonary bypass technique for animal experiments on implantable ventricular assist devices.

We have developed and report on a simplified cardiopulmonary bypass technique for experiments on implantable ventricular assist devices in calves. We used an electromechanical implantable ventricular assist device with a double cylindrical cam in three calves. Cannulas for the ventricular assist system were designed to be inserted between the left atrium and the descending aorta. We used the ou...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Modulation of circulating endothelin-1 and big endothelin by nitric oxide inhalation following left ventricular assist device implantation.

BACKGROUND Inhaled nitric oxide (iNO) is an established therapy in the treatment of pulmonary hypertension and right ventricular dysfunction following left ventricular assist device implantation. Since it is known that endothelin-1 contributes to pulmonary hypertension, and nitric oxide modulates endothelin-1 synthesis in vitro, we investigated the effects of iNO on circulating endothelin-1 and...

متن کامل

Right ventricular support after implantation of a Novacor Left Ventricular Assist Device.

The objective was to determine which factors might help to predict the need for mechanical right ventricular support following insertion of a left ventricular assist device (LVAD). A retrospective analysis was performed on 24 patients with cardiomyopathies who had insertion of a LVAD as a bridge to heart transplantation at Presbyterian University Hospital during the period 1987 to 1991. Group...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997