Background 4D flow MRI has the potential to provide global quantification of cardiac flow in a single acquisition [Hsiao, 2012]. However, 4D flow data are often compromised by low velocity-to-noise ratio, potentially caused by MRI acceleration or unfitting vencs. Since blood flow is approximately divergence-free, noise level can be reduced by removing divergence from noisy flow data [Song, 1993] [Busch, 2012]. On the other hand, strict enforcement of divergence-free condition distorts flow around edges as discrete approximation of flow near edges creates divergence. In this current work, we aim to provide an adjustable and fast operation of imposing multi-scale divergence-free conditions on flow data by using divergence-free wavelets. In addition, we utilize the sparsity of flow data in divergencefree wavelet domain [Deriaz, 2006] for further denoising by performing wavelet shrinkage [Donoho, 1995].
منابع مشابه
Robust 4D flow denoising using divergence-free wavelet transform.
PURPOSE To investigate four-dimensional flow denoising using the divergence-free wavelet (DFW) transform and compare its performance with existing techniques. THEORY AND METHODS DFW is a vector-wavelet that provides a sparse representation of flow in a generally divergence-free field and can be used to enforce "soft" divergence-free conditions when discretization and partial voluming result i...
متن کاملComprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance
BACKGROUND Phase contrast cardiovascular magnetic resonance (CMR) is able to measure all three directional components of the velocities of blood flow relative to the three spatial dimensions and the time course of the heart cycle. In this article, methods used for the acquisition, visualization, and quantification of such datasets are reviewed and illustrated. METHODS Currently, the acquisiti...
متن کاملOn interpolatory divergence-free wavelets
We construct interpolating divergence-free multiwavelets based on cubic Hermite splines. We give characterizations of the relevant function spaces and indicate their use for analyzing experimental data of incompressible flow fields. We also show that the standard interpolatory wavelets, based on the Deslauriers-Dubuc interpolatory scheme or on interpolatory splines, cannot be used to construct ...
متن کاملAccelerated 4D flow imaging using randomly undersampled echo planer imaging with compressed-sensing reconstruction
Introduction 2D phase contrast (PC) CMR is currently the standard clinical imaging sequence for evaluation of blood flow [1]. Recently, 3D time-resolved PC CMR (4D-PC) has been used for quantification and visualization of blood flow in all three directions of a volume [2]. However, such acquisitions require long scan times (often 10-20 minutes), which reduces its clinical feasibility and leads ...
متن کامل4D flow MRI of the aorta becomes practical: performance and observer variability for a new semi-automated workflow for 3D visualization and quantification of aortic hemodynamics
Background To systematically investigate the performance and interobserver variability of a new standardized workflow for the analysis of aortic hemodynamics based on 4D-flow MRI in a study with 30 subjects. The semi-automated workflow was developed to ensure faster and standardized data analysis including systematic placement of analysis planes, 3D-flow visualization, and quantification of sta...
متن کامل