Positive Feedback in Powered Exoskeletons: Improved Metabolic Efficiency at the Cost of Reduced Stability?

نویسندگان

  • James A. Norris
  • Anthony P. Marsh
  • Kevin P. Granata
  • Shane D. Ross
چکیده

* Associate Professor and author of correspondence, Phone: (336) 758-4643, Fax: (336) 758-4680, Email: [email protected]. ABSTRACT A broad objective of many lower extremity exoskeletons is to allow the wearer to expend less of their own energy for locomotion. Existing exoskeleton control algorithms are based on positive feedback. Forces are generated to augment movement initiated by the wearer. Positive feedback, however, can have destabilizing effects in dynamic systems. In fact, stability in these lower extremity exoskeletons is achieved by relying on the wearer’s neuromuscular system. Relying on the wearer to maintain stability may increase metabolic demand, which is counter productive to increasing efficiency. Thus, the goal of this study was to measure how a simple form of positive feedback that augments ankle push-off power affects both metabolic efficiency and dynamic walking stability. We developed a pair of powered ankle-foot orthoses (PAFOs) similar in design to Ferris, et al. (J. Appl. Biomech. 21, 189197, 2005). Nine young healthy adults (23.3!1.6 years) walked on a treadmill in the PAFOs under two conditions: (1) with and (2) without push-off power assistance. Metabolic energy expenditure was calculated using indirect calorimetry. Walking stability was quantified using techniques for studying stability of dynamic system trajectories. The maximum Lyapunov exponent for assessing local dynamic stability, and the maximum Floquet multiplier magnitude for assessing orbital stability were calculated from foot and shank kinematics for each condition. Greater Lyapunov exponents and Floquet multipliers indicate decreased stability. Walking with mechanically generated push-off power increased metabolic efficiency (2.58!0.39 to 2.97!0.38, p<0.01), did not affect local dynamic stability (0.14!0.02 to 0.14!0.02, p=0.77), but decreased orbital dynamic stability (0.43!0.03 to 0.48!0.06, p=0.05). This study provides evidence that positive feedback can negatively affect stability. Further investigations into understanding stability of movement will be necessary for the design of controllers for powered lower extremity exoskeletons.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Powered ankle exoskeletons reveal the metabolic cost of plantar flexor mechanical work during walking with longer steps at constant step frequency.

We examined the metabolic cost of plantar flexor muscle-tendon mechanical work during human walking. Nine healthy subjects walked at constant step frequency on a motorized treadmill at speeds corresponding to 80% (1.00 m s(-1)), 100% (1.25 m s(-1)), 120% (1.50 m s(-1)) and 140% (1.75 m s(-1)) of their preferred step length (L(*)) at 1.25 m s(-1). In each condition subjects donned robotic ankle ...

متن کامل

Mechanics and energetics of level walking with powered ankle exoskeletons.

Robotic lower limb exoskeletons that can alter joint mechanical power output are novel tools for studying the relationship between the mechanics and energetics of human locomotion. We built pneumatically powered ankle exoskeletons controlled by the user's own soleus electromyography (i.e. proportional myoelectric control) to determine whether mechanical assistance at the ankle joint could reduc...

متن کامل

Mechanics and energetics of incline walking with robotic ankle exoskeletons.

We examined healthy human subjects wearing robotic ankle exoskeletons to study the metabolic cost of ankle muscle-tendon work during uphill walking. The exoskeletons were powered by artificial pneumatic muscles and controlled by the user's soleus electromyography. We hypothesized that as the demand for net positive external mechanical work increased with surface gradient, the positive work deli...

متن کامل

Influence of Power Delivery Timing on the Energetics and Biomechanics of Humans Wearing a Hip Exoskeleton

A broad goal in the field of powered lower limb exoskeletons is to reduce the metabolic cost of walking. Ankle exoskeletons have successfully achieved this goal by correctly timing a plantarflexor torque during late stance phase. Hip exoskeletons have the potential to assist with both flexion and extension during walking gait, but the optimal timing for maximally reducing metabolic cost is unkn...

متن کامل

A Novel Photovoltaic Powered Reverse Osmosis with Improved Productivity of Reverse Osmosis and Photovoltaic Panel

With the increasing installed capacity of desalination, the greenhouse gas emission for generating the required energy to power the desalination plants is also becoming the focus of attention in the world community. Domestic reverse osmosis membranes have been very successful technology especially in the developing world to provide safe drinking water. The novel concept of photovoltaic powered ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007