Stability of Unicortical versus Bicortical Metacarpal Fracture Internal Fixation Trial (SUBMIT): study protocol for a randomized controlled trial

نویسندگان

  • Feiran Wu
  • Katie Young
  • Mohammad Shahid
  • Peter Nightingale
  • Surabhi Choudhary
  • Michael Craigen
  • Rajive Jose
  • Mark Foster
چکیده

BACKGROUND Metacarpal fractures are common, accounting for 40 % of all hand injuries. The use of plates for the fixation of these fractures allows early aggressive hand therapy post-operatively, reducing post-operative stiffness. Traditionally, bicortical fixation is the standard practice, where both dorsal and palmar cortices of the metacarpal are drilled through, with screws engaging both cortices. Recent biomechanical studies have shown that unicortical fixation, where only the near cortex is drilled and engaged by the screw, results in no difference in stiffness, load to failure or failure mechanism, when compared with bicortical fixation. This trial aims to compare fracture union, complication rate and functional outcomes between unicortical and bicortical fixation for adults with displaced metacarpal fractures. METHODS/DESIGN All adults with displaced diaphyseal metacarpal fracture requiring plate fixation are potentially eligible to take part in this study. A total of 315 consenting patients will be randomly allocated to either unicortical or bicortical plate and screw fixation. The surgery will be performed in specialist hand trauma units across the UK. Data regarding fracture healing, hand function, quality of life, and complications will be collected at 2 weeks, 6 weeks and 6 months following surgery. DISCUSSION This pragmatic, prospective, multi-centre, randomized controlled trial is expected to deliver results in 2018. TRIAL REGISTRATION ISRCTN 18006607 . Registered on 19 Nov 2015.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A biomechanical study comparing plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to cyclic loading.

The use of bicortical screws to fix metacarpal fractures has been suggested to provide no added biomechanical advantage over unicortical screw fixation. However, this was only demonstrated in static loading regimes, which may not be representative of biological conditions. The present study was done to determine whether similar outcomes are obtained when cyclic loading is applied. Transverse mi...

متن کامل

A biomechanical analysis of plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to 4-point bending and dynamical bending test

In the published literature there are controversial data to the biomechanical stability of monocortical comparing to the bicortical fixation of metacarpal fractures. The aim of this study was to compare the biomechanical stability of monocortical and bicortical locking osteosynthesis in quasi-static and dynamic 4-point bending tests of composite third metacarpal bone (4th Gen third metacarpal, ...

متن کامل

Unicortical versus bicortical locked plate fixation in midshaft clavicle fractures.

Higher rates of poor outcomes in displaced midshaft clavicle fractures treated nonoperatively have recently been reported. Along with expanding indications for operative fixation and increasing application of locked plate constructs, it is unknown whether complications related to bicortical penetration of the clavicle can be avoided using unicortical fixation. The purpose of this study is to co...

متن کامل

Biomechanical Comparison of Bicortical, Unicortical, and Unicortical Far-Cortex-Abutting Screw Fixations in Plated Comminuted Midshaft Clavicle Fractures.

PURPOSE The objective of this study was to assess the biomechanical properties of bicortical locking screws, unicortical locking screws, and unicortical far-cortex-abutting locking screw fixation in a cadaver model of comminuted midshaft clavicle fractures stabilized with a locking plate placed on the superior surface of the clavicle. METHODS Nine pairs of adult fresh-frozen cadaver clavicles...

متن کامل

Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: a cadaveric model.

OBJECTIVE The purpose of this study was to compare the biomechanical properties of bicortical with unicortical screws in a proximal tibial fracture cadaveric model. SETTING Biomechanics laboratory at a Level 1 trauma center. PATIENTS/PARTICIPANTS Eight pairs (4 male and 4 female) of elderly (average age, 79 years; range, 63 to 104 years) cadaveric tibiae. INTERVENTION Osteotomies were per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016