Comparison between pressure-recording analytical method (PRAM) and femoral arterial thermodilution method (FATD) cardiac output monitoring in an infant animal model of cardiac arrest

نویسندگان

  • Javier Urbano
  • Jorge López
  • Rafael González
  • Sarah N. Fernández
  • María José Solana
  • Blanca Toledo
  • Ángel Carrillo
  • Jesús López-Herce
چکیده

BACKGROUND The pressure-recording analytical method is a new semi-invasive method for cardiac output measurement (PRAM). There are no studies comparing this technique with femoral artery thermodilution (FATD) in an infant animal model. METHODS A prospective study was performed using 25 immature Maryland pigs weighing 9.5 kg. Fifty-eight simultaneous measurements of cardiac index (CI) were made by FATD and PRAM at baseline and after return of spontaneous circulation. Differences, correlation, and concordance between both methods were analyzed. The ability of PRAM to track changes in CI was explored with a polar plot. RESULTS Mean CI measurements were 4.5 L/min/m(2) (95 % CI, 4.2-4.8 L/min/m(2); coefficient of variation, 27 %) by FATD and 4.0 L/min/m(2) (95 % CI, 3.6-4.3 L/min/m(2); coefficient for variation, 37 %) by PRAM (difference, 0.5 L/min/m(2); 95 % CI for the difference, 0.1-1.0 L/min/m(2); p = 0.003; n = 58). No correlation between both methods was observed (r = 0.170, p = 0.20). Limits of agreement were -2.9 to 4.0 L/min/m(2) (-69.9 to 84.9 %). Percentage error was 80.6 %. Only 26.1 % of data points lied within an absolute deviation of ±30° from the polar axis. CONCLUSIONS No correlation nor concordance between both methods was observed. Limits of agreement and percentage of error were high and clinically not acceptable. No concurrence between both methods in CI changes was observed. PRAM is not a useful method for measurement of the CI in this pediatric model of cardiac arrest.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states.

BACKGROUND Cardiac output (CO) can be measured using the pressure recording analytical method (PRAM), which is a new, less invasive technique allowing beat-by-beat stroke volume monitoring from the pressure signals recorded in femoral or radial arteries. METHODS We investigated PRAM by comparing its cardiac output (PRAM-CO) with paired measurements obtained by electromagnetic flowmetry (EM-CO...

متن کامل

Lack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients.

BACKGROUND Pulse-contour analysis method (PCM) cardiac output (CO) monitors are increasingly used for CO monitoring during anaesthesia and in the critically ill. Very recently, several systems have been introduced that do not need calibration; among them the pressure recording analytical method (PRAM). Sparse data comparing the accuracy of the PRAM-CO with conventional thermodilution CO (ThD-CO...

متن کامل

Cardiac output monitoring by pressure recording analytical method in cardiac surgery.

OBJECTIVE A less-invasive method has been developed that may provide an alternative to monitor cardiac output from arterial pressure: beat-to-beat values of cardiac output can be obtained by pressure recording analytical method (PRAM). The purpose of this study was to assess the reliability of cardiac output determination by PRAM in cardiac surgery. METHODS Cardiac output was measured in 28 p...

متن کامل

Cardiac index assessment by the pressure recording analytic method in critically ill unstable patients after cardiac surgery.

OBJECTIVE The authors measured cardiac index in unstable patients after cardiac surgery with the Pressure Recording Analytic Method (PRAM) and compared it with the reference method of thermodilution (ThD) with the pulmonary artery catheter; using the hypothesis that there were no significant differences between the 2 methods. DESIGN A prospective study. SETTING Cardiac surgery intensive car...

متن کامل

Cardiac output by arterial pulse contour: reliability under hemodynamic derangements.

Pulse contour methods (PCM) for the measurements of cardiac output (CO) are gaining popularity in intensive care settings but their reliability during hemodynamic instability has been questioned. Pressure-recording-analytical-method (PRAM) is a newly developed uncalibrated hemodynamic monitor and its capability in measuring CO during hemodynamic instability is still under investigation. Dobutam...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016